Set door held warning time

K44 Duo Installation & User manual

19

Set door held warning time

If the door is still open when the opening time has expired, a buzzer sounds as to remind the visitor to close the door immediately – or the alarm output will be activated. The buzzer sounds until the door is closed.

Note that door contacts must be connected and that Door control must be activated for this to work. This is how to change the door held warning time, if needed:

1� Enter A29.

2� Enter the desired door held warning time (01-99) with two digits, e.g. 09 for 9 seconds.

3� Choose to which relay outputs the new door held warning time should apply:

0 = both

1 = relay output 1

2 = relay output 2