L-850D/E F-Range Style 2 Inset Lights

Maintenance

Workshop maintenance and preventive maintenance, continued

Preventive

In the table below you will find a checklist of preventive maintenance tasks:

maintenance

 

 

 

tasks

 

 

 

Interval

Check

 

Action

 

 

 

Daily

for lamp failure

Replace lamp and film disc cut-out (if any).

 

 

 

 

 

for low light output

1.

Clean outer surface of prism if dirty.

 

 

2.

Check for misalignment or presence of moisture

 

 

in fixture.

 

 

3.

Check for lamp ageing or displacement

 

 

 

Weekly

for obstruction in light output

Clean channel and prism surface

 

channel

 

 

Monthly *

for presence of moisture or

1.

Open up light assembly.

 

water (visual inspection on

2.

Clean, dry and inspect.

 

condensation inside of

 

 

 

 

prisms)

3.

Replace O-ring and other parts found defective.

 

 

 

Bimonthly

torque on hold-down bolts

Refer to the table “Screws Overview” on page 43

 

 

for the tool to use, the torque to apply, and the

 

 

eventual use of “Loctite” sealing compound.

Semi-annually *

for presence of water in

1.

Pump water from base.

 

base

2.

Remove, dismantle and inspect light for water

 

 

 

 

damage.

 

 

3.

Cure the cause of water ingress.

 

 

 

After 800 hours

Replace lamps of complete

It is recommended to replace the lamps

of operation at

subsystems (e.g. R/W

systematically when 80 % of the useful life has

6.6 A

centreline)

been reached. At full brightness (6.6 A), it

 

 

represents 800 hours, but, in practice, life spans of

 

 

2000 to 4000 hours can be expected.

After snow

for damaged light fixtures

1.

Replace badly damaged fixtures.

removal

 

2.

Use a power broom for snow removal in the

 

 

 

 

vicinity of the light fixture, if practical.

 

 

3.

Follow recommended snow removal techniques

 

 

described in FAA AC 150/5200-23 to avoid or at

 

 

least to reduce damage to light fixtures.

* More frequently during rainy seasons.

2002 Siemens Airfield Solutions, Incorporated

96A0266D

18

All rights reserved

Issued 2/02

 

Page 20
Image 20
Siemens L-850D/E F-Range Style 2 Inset Lights manual Preventive, Maintenance Tasks Interval Check Action