Maintenance

How to lift the light fixture out of the base or adapter ring

Lifting tools

 

Siemens Airfield Solutions has developed 2 models of lifting tools (see illustrations

 

 

below):

 

 

 

Model a: simple tool used when the light fixture can be easily removed;

 

 

Model b: a more sturdy tool to remove the light fixture in more difficult

 

 

conditions.

 

 

 

 

Procedure

 

To lift the optical unit out of the base receptacle or adapter ring, proceed as follows:

 

 

 

 

 

 

Step

Action

 

 

 

 

 

 

1

Remove the six fixing screws and washers (A1-A2) or self locking nuts.

 

 

 

 

 

 

2

Fit the appropriate lifting tool (see figure below) into both holes located

 

 

 

(180° apart) in the cover (B1), lift the optical unit out of the Eurobase or

 

 

 

adapter ring and place it next to it.

 

 

3

Disconnect the light fixture wires from the power wires coming from the

 

 

 

transformer(s).

 

 

4

Take the optical unit back to the maintenance base where it can be

 

 

 

serviced entirely.

 

 

Never hold the light fixture by the wires as this may damage the insulation, break

 

 

the waterproof seal and cause insulation faults and water leakage.

 

 

 

 

 