Maintenance |
How to lift the light fixture out of the base or adapter ring
Lifting tools |
| Siemens Airfield Solutions has developed 2 models of lifting tools (see illustrations | |
|
| below): |
|
|
| • Model a: simple tool used when the light fixture can be easily removed; | |
|
| • Model b: a more sturdy tool to remove the light fixture in more difficult | |
|
| conditions. | |
|
|
|
|
Procedure |
| To lift the optical unit out of the base receptacle or adapter ring, proceed as follows: | |
|
|
|
|
|
| Step | Action |
|
|
|
|
|
| 1 | Remove the six fixing screws and washers |
|
|
|
|
|
| 2 | Fit the appropriate lifting tool (see figure below) into both holes located |
|
|
| (180° apart) in the cover (B1), lift the optical unit out of the Eurobase or |
|
|
| adapter ring and place it next to it. |
|
| 3 | Disconnect the light fixture wires from the power wires coming from the |
|
|
| transformer(s). |
|
| 4 | Take the optical unit back to the maintenance base where it can be |
|
|
| serviced entirely. |
|
| Never hold the light fixture by the wires as this may damage the insulation, break | |
|
| the waterproof seal and cause insulation faults and water leakage. | |
|
|
| |
|
| The illustration below clarifies the procedure: |
2002 Siemens Airfield Solutions, Incorporated | 96A0266D | 19 |
All rights reserved | Issued 2/02 |
|