Siemens MCM 1755 NTD manuel dutilisation Error handling

Models: MCM 1755 NTD

1 34
Download 34 pages 47.1 Kb
Page 34
Image 34

Color monitor MCM 1755 NTD

Error handling

If an error occurs, first check the points listed below. If you cannot solve the problem, please contact our customer service.

The display is too small or not centered

The monitor recognizes an undefined mode.

ÊAdjust the picture size, position and edges (see "Operation of the monitor").

Color displacements

You must degauss the monitor.

ÊBriefly press the degauss button (see "Operation of the monitor").

"CHECK SIGNAL CABLE" display appears

The data cable is not connected or is incorrectly connected to the monitor or the system unit.

ÊCheck the connectors.

No display (power lamp does not light)

Possible causes:

Monitor ON/OFF switch is not switched on

System unit is not switched on

Power cable not plugged into system unit

ÊCheck the above points.

No display (power lamp lights)

Possible causes:

Power management is active

System unit is not switched on

Brightness and/or contrast incorrectly set

ÊCheck the above points.

26 - English

A26361-K472-Z100-2-5E19

Page 34
Image 34