6. Data Filter Command

Si4421

Bits 4-3 (g1 to g0):

LNA gain select:

g1

g0

Gain relative to maximum [dB]

0

0

0

0

1

-6

1

0

-14

1

1

-20

Bits 2-0 (r2 to r0): RSSI detector threshold:

r2

r1

r0

RSSIsetth

0

0

0

-103

0

0

1

-97

0

1

0

-91

0

1

1

-85

1

0

0

-79

1

0

1

-73

1

1

0

Reserved

1

1

1

Reserved

The RSSI threshold depends on the LNA gain, the real RSSI threshold can be calculated:

RSSIth =RSSIsetth+GLNA

6. Data Filter Command

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

POR

 

1

1

0

0

0

0

1

0

al

ml

1

s

1

f2

f1

f0

C22Ch

Bit 7 (al): Clock recovery (CR) auto lock control

1:auto mode: the CR starts in fast mode, after locking it switches to slow mode. Bit 6 (ml) has no effect.

0:manual mode, the clock recovery mode is set by Bit 6 (ml)

Bit 6 (ml): Clock recovery lock control

1:fast mode, fast attack and fast release (4 to 8-bit preamble (1010...) is recommended)

0:slow mode, slow attack and slow release (12 to 16-bit preamble is recommended)

Using the slow mode requires more accurate bit timing (see Data Rate Command, page 17).

Bit 4 (s): Select the type of the data filter:

s

0

1

Filter Type

Digital filter

Analog RC filter

Digital: This is a digital realization of an analog RC filter followed by a comparator with hysteresis. The time constant is automatically adjusted to the bit rate defined by the Data Rate Command (page 17).

Note: Bit rate cannot exceed 115 kpbs in this mode.

Analog RC filter: The demodulator output is fed to pin 7 over a 10 kOhm resistor. The filter cut-off frequency is set by the external capacitor connected to this pin and VSS.

The table shows the optimal filter capacitor values for different data rates

Data Rate [kbps]

1.2

2.4

4.8

9.6

19.2

38.4

57.6

115.2

256

Filter Capacitor Value

12 nF

8.2 nF

6.8 nF

3.3 nF

1.5 nF

680 pF

270 pF

150 pF

100 pF

Note: If analog RC filter is selected the internal clock recovery circuit and the FIFO cannot be used.

19

Page 19
Image 19
Silicon Laboratories SI4421 manual Si4421, Data Filter Command