Si4421
Control Commands
|
|
| Control Command |
| Related Parameters/Functions |
| Related control bits |
1 |
|
| Configuration Setting Command |
| Frequency band, crystal oscillator load capacitance, | el, ef, b1 to b0, x3 to x0 | |
|
|
| RX FIFO and TX register enable |
| |||
|
|
|
|
|
|
| |
|
|
|
|
| Receiver/Transmitter mode change, | synthesizer, |
|
2 |
|
| Power Management Command |
| crystal oscillator, PA, | clock output | er, ebb, et, es, ex, eb, ew, dc |
|
|
|
|
| enable |
|
|
3 |
|
| Frequency Setting Command | Frequency of the local oscillator/carrier signal | f11 to f0 | ||
4 |
|
| Data Rate Command |
| Bit rate |
| cs, r6 to r0 |
5 |
|
| Receiver Control Command |
| Function of pin 16, Valid Data Indicator, baseband | p16, d1 to d0, i2 to i0, g1 to g0, r2 | |
|
|
| bandwidth, LNA gain, digital RSSI threshold | to r0 | |||
|
|
|
|
| |||
6 |
|
| Data Filter Command |
| Data filter type, clock recovery parameters | al, ml, s, f2 to f0 | |
7 |
|
| FIFO and Reset Mode Command |
| Data FIFO IT level, FIFO start control, FIFO enable | f3 to f0, sp, ff, al, dr | |
|
|
| and FIFO fill enable, POR sensitivity |
| |||
|
|
|
|
|
|
| |
8 |
|
| Synchron Pattern Command | Synchron pattern |
| b7 to b0 | |
9 |
|
| Receiver FIFO Read Command | RX FIFO read |
|
| |
10 |
|
| AFC Command | AFC parameters |
| a1 to a0, rl1 to rl0, st, fi, oe, en | |
11 |
|
| TX Configuration Control Command | Modulation parameters, output power | mp, m3 to m0, p2 to p0 | ||
12 |
|
| PLL Setting Command | CLK out buffer speed, dithering, PLL bandwidth | ob1 to ob0, ddit, dly, bw0 | ||
13 |
|
| Transmitter Register Write Command | TX data register write |
| t7 to t0 | |
14 |
|
|
| r4 to r0, m7 to m0 | |||
15 |
|
| Low |
| Enable and set low |
| d6 to d0, en |
|
|
| Low Battery Detector and |
|
|
|
|
16 |
|
| Microcontroller Clock Divider | LBD voltage and microcontroller clock division ratio | d2 to d0, v3 to v0 | ||
|
|
| Command |
|
|
|
|
17 |
|
| Status Read Command | Status bit readout |
|
|
In general, setting the given bit to one will activate the related function. In the following tables, the POR column shows the default values of the command registers after
Control Register Default Values
| Control Register | |
1 | Configuration Setting Command | 8008h |
2 | Power Management Command | 8208h |
3 | Frequency Setting Command | A680h |
4 | Data Rate Command | C623h |
5 | Receiver Control Command | 9080h |
6 | Data Filter Command | C22Ch |
7 | FIFO and Reset Mode Command | CA80h |
8 | Synchron Pattern Command | CED4h |
9 | Receiver FIFO Read Command | B000h |
10 | AFC Command | C4F7h |
11 | TX Configuration Control Command | 9800h |
12 | PLL Setting Command | CC77h |
13 | Transmitter Register Write Command | B8AAh |
14 | E196h | |
15 | Low | C80Eh |
16 | Low Battery Detector and Microcontroller Clock Divider Command | C000h |
17 | Status Read Command | 0000h |
14