ELECTRICAL SPECIFICATIONS
POWER SUPPLY
The following voltage specification applies to the drive power connector. Connections to the drive should be made in a safety extra low voltage (SELV) circuit.
The drive does not use the +5V supply input pins available on a typical 
Adequate secondary 
CAUTION: To avoid damage to the drive, power supply voltage transients must not exceed 16 volts.
POWER REQUIREMENTS
The ZeusIOPS 
Table 5. ZeusIOPS 
Item  | Requirement  | 
  | 
  | 
Input Voltage  | 12V   | 
  | 
  | 
Minimum Voltage  | 10.8  | 
  | 
  | 
Maximum Voltage  | 13.2  | 
  | 
  | 
POWER CONSUMPTION
Table 6. ZeusIOPS Fibre Channel SSD Typical Power Consumption
Activity | Average Current (mA) | Average Power (W) | 
  | 
  | 
  | 
Startup  | 1,200  | 14.4  | 
  | 
  | 
  | 
Idle  | 450  | 5.4  | 
  | 
  | 
  | 
Max Read @ 200MB/sec  | 700  | 8.4  | 
  | 
  | 
  | 
Max Write @ 100MB/sec  | 675  | 8.1  | 
  | 
  | 
  | 
Read, 1 Block Random I/O @ > 50,000  | 525  | 6.3  | 
  | 
  | 
  | 
Write, 1 Block Random I/O @ > 18,000  | 660  | 7.9  | 
  | 
  | 
  | 
28  | ZeusIOPS   |