WRITE EXTENDED (10) (2Ah)

The WRITE (10) EXTENDED (2Ah) command requests that the drive write the data transferred by the initiator to the medium. Bytes 1 and 9 are ignored.

 

 

 

Table 25.

Write Extended (10) (2Ah) CDB

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit

7

6

 

5

 

4

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

Operation Code (2Ah)

 

 

 

 

 

 

 

 

 

 

 

 

1

Logical Unit Number (RSVD)

 

DPO

FUA

 

Reserve

Reserve

RelAdr

 

 

 

 

 

 

 

 

 

 

 

 

2

(MSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

Logical Block Address

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

(MSB)

 

 

 

 

Transfer Length

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WRITE AND VERIFY (10) (2Eh)

The WRPROTECT field and DPO and BYTCHK bits in CDB Byte 1 are all ignored.

VERIFY (10) (2Fh)

The VRPROTECT field in Byte 1 is ignored. If the DPO and BYTCHK bits in CDB Byte 1 are not both zero, or the GROUP NUMBER field in Byte 6 is non-zero, the command is rejected. If any bit in Byte 1 is set other than LUN, or if any bits in Bytes 6 and 9, an Invalid field in the CDB is reported.