SimpleTech ZeusIOPS manual Selectid Configurations, Bit Bits 5 Configuration Result

Models: ZeusIOPS

1 84
Download 84 pages 7.29 Kb
Page 66
Image 66

SINGLE CHANNEL MODE FOR EARLY REVISION DRIVES

On early revisions of the drive, JP1 did not exist. These drives are identified by having a serial number of “50” or less and only have an 8-way right-angled manufacturing connector. For this revision of drive, the feature is enabled by setting bit 6 of the LOOP_ID to “1”. The LOOP_ID is set using the SELECT_ID pins on the SCA-2 connector within the chassis to which the SSD is connected. See the SEL_ID Function on page 30.

The SELECT_ID bits are normally configured by jumpers or a switch that allows the ID of the drive to be set using the backplane of the SCA-2 connector. Table 39 lists the various configurations of the SELECT_ID function.

Table 39. SELECT_ID Configurations

Bit 6

Bits 5 -1

Bit 0

Configuration Result

 

 

 

 

0

XXXXX

X

Loop ID 0 - 63

 

 

 

Drive operates down both channels.

 

 

 

 

1

XXXXX

0

Loop ID 64 - 126 and even

 

 

 

Drive operates down channel A only.

 

 

 

 

1

XXXXX

1

Loop ID 65 - 127 and odd

 

 

 

Drive operates down channel B only.

 

 

 

 

66

ZeusIOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0

Page 66
Image 66
SimpleTech ZeusIOPS manual Selectid Configurations, Bit Bits 5 Configuration Result