56h

Reserve (10). Obsolete, but supported.

 

 

57h

Release (10). Obsolete, but supported.

 

 

5Eh

Persistent Reserve In

 

 

5Fh

Persistent Reserve Out

 

 

REPORT LUNS (A0h)

The REPORT LUNS command will request that the peripheral device logical unit inventory accessible to the I_T nexus be sent to the application client. The logical unit inventory is a list that shall include the logical unit numbers of all logical units having a Peripheral Qualifier value of 000b. Logical unit numbers for logical units with Peripheral Qualifier values other than 000b and 011b may be included in the logical unit inventory. Logical unit numbers for logical units with a Peripheral Qualifier value of 011b are excluded from the logical unit inventory. The ZeusIOPS SSD only appears as a single LUN (Logical Unit Number). Byte 2 and Byte 11 are ignored.

Table 13. Report Luns Command

Bit

7

6

5

 

4

 

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

Operation Code (A0h)

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

Select Report

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

(MSB)

 

 

 

Allocation Length

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 