SimpleTech ZeusIOPS manual Mode Sense CDB, Code Field Descriptions

Models: ZeusIOPS

1 84
Download 84 pages 7.29 Kb
Page 43
Image 43

MODE SENSE (6) COMMAND (1Ah)

The MODE SENSE (6) command provides a means for a target to report parameters to the initiator. It is a complementary to the MODE SELECT (6) command. See Tables 19 and 20.

Table 19. Mode Sense CDB

Bit

7

 

6

5

4

3

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

Operation Code (1Ah)

 

 

 

 

 

 

 

 

 

 

1

Logical Unit Number (RSVD)

Reserve

DBD

 

Reserved

 

 

 

 

 

 

 

 

 

 

2

 

PC

 

 

Page Code

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

Allocation Length

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

Control

 

 

 

 

 

 

 

 

 

 

 

 

 

A Disable Block Descriptors (DBD) bit of zero indicates that the target may return zero or more block descriptors in the returned MODE SENSE data, at the target's discretion. A DBD bit of one specifies that the target shall not return any block descriptors in the returned MODE SENSE data. The page control (PC) field defines the type of mode parameter values to be returned in the mode pages. The page code specifies which mode page to return.

Table 20. Page Code Field Descriptions

Page Code

Description

Subclause

 

 

 

00h

Vendor-specific (does not require page format)

 

 

 

 

01h - 1Fh

See specific device-types

 

 

 

 

20h - 3Eh

Vendor-specific (page format required)

 

 

 

 

3Fh

Return all mode pages

 

 

 

 

ZeusIOPS 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0

43

Page 43
Image 43
SimpleTech ZeusIOPS manual Mode Sense CDB, Code Field Descriptions, Reserved Code Allocation Length Control