Fault tracing

7.7Rudder movement stops as water pressure on the rudder increases.

(J1000B, J101A, J45A only) Probable reasons:

1.Overload. Check whether the r.p.m. of the motor is too low. Eventually turn potentiometer RV1 in junction unit clockwise (CW) until rudder movement is recovered.

7.8When on automatic steering, the boat swings from side to side without stabilizing after course changes

(J1000B, J101A, J45A only) Probable reasons:

1.The rudder movement is too slow. Correct as in paragraph 7.7

2.Wrong setting of the autopilot. Refer to the set-up procedure for the autopilot.

7.9Small and sudden heading changes while on automatic steering

(J1000B, J101A, J45A only) Probable reasons:

1.The rudder movement is too fast. Turn potentiometer RV1 in junction unit counter-clockwise (CCW) until optimum rudder speed is achieved.

2.Refer to paragraph 7.8.2.