Simran RPU80 instruction manual Activator reduces the hardening time to 1 hour

Models: RPU80

1 38
Download 38 pages 40.83 Kb
Page 30
Image 30
"Activator" reduces the hardening time to 1 hour).

Simrad Reversible Pump RPU80/160/300

7.10Rudder moves only in one direction (with pump running)

 

Probable reason:

 

Suction valve not working (pos. 20, 9, 21) on one side. This is

 

most probably caused by metal fragments that have entered into

 

the suction valve(s) through the tube fitting for the return line

 

(C) during installation. Ref. figure 3-1.

 

The suction valve (3) on the side that is not giving pressure must

 

be opened and thoroughly cleaned, and for safety reasons the

 

other valve should also be inspected and cleaned before

 

reinstalling the pump unit.

 

For disassembling and cleaning of the suction valves please use

 

following procedure (Ref. figure 9-1):

 

1.

Unscrew the grub screw - pos. 21.

 

2.

Remove the spring - pos. 9, and the steel ball - pos. 20.

 

3.

Thoroughly clean the valve seat and the threads in the valve

 

 

block (1). Also clean the removed steel ball (20), spring (9)

 

 

and grub screw (21). Use Loctite "Super Clean" or similar.

 

Reassemble as follows:

 

1.

Put the steel ball (20) into the valve block.

 

2.

Put the spring (9) onto the grub screw (21) before it is

 

 

screwed into the valve block.

Note !

Use Loctite 542 or similar on the threads to prevent oil leakage.

 

If Loctite 747 "Activator" is sprayed on the threads before

 

applying Loctite 542, this will speed up the hardening

 

process.(With Loctite 542 only, you have to wait 4 hours before

 

the pump unit can be put in operation again. Using Loctite

 

"Activator" reduces the hardening time to 1 hour).

 

3.

Make sure the grub screw (21) is screwed in until it is flush

 

 

with the valve block (1). This will ensure correct spring

 

 

tension in the suction valve.

28

20220422N

www.Busse-Yachtshop.de email: info@busse-yachtshop.de

Page 30
Image 30
Simran RPU80 instruction manual Activator reduces the hardening time to 1 hour