Simran instruction manual Simrad Reversible Pump RPU80/160/300

Models: RPU80

1 38
Download 38 pages 40.83 Kb
Page 8
Image 8
Manual background

Simrad Reversible Pump RPU80/160/300

An automatic "Rudder test" function in these autopilots will also limit the output equivalent to a rudder speed of 8 degrees per second which is optimum for autopilots with proportional rudder control. (Equals to approx. 9 seconds for 35-0-35 degrees rudder travel). Consequently when operating a steering lever or the Port/Stbd push buttons on the autopilot in manual mode, the rudder speed will be 8 degrees per second, whilst the rudder speed when in "Auto" mode normally is less and proportional to the heading error.

If the pump unit is used with older autopilot models like AP2500, AP200 or AP45, using J1000B, J101A or J45A junction units, the output level/flow rate is set by a potentiometer within the junction unit.

External rudder speed control can be provided by a separate potentiometer connected to J1000B/J101A/J45A and mounted near the steering position.

The flow rate must be chosen such that optimum automatic steering is obtained.

Experience has shown that a rudder time between 10 and 15 seconds hard over to hard over normally gives the best steering performance. In order to achieve a rudder time within these limits, the flow rate must correspond with the cylinder volume.

Some boats will perform good automatic steering even with a hardover time of 20 seconds. The flow-rate, however, is reduced by increasing load, i.e. increased pressure. It is therefore not recommended to select a pump with a flow rate that is not able to move the rudder hardover to hardover in 20 seconds as shown on the nomogram on page 13. Study the tables on the following pages for appropriate pump selection, and use the nomogram on page 13 as a guideline.

On page 7 to 11 are listed some well known hydraulic steering gears together with the corresponding values for the rudder time hardover to hardover.

The values are calculated from the maximum flow rate at 10 bar pressure.

If a specific system is not listed, the cylinder volume must be calculated as explained in section 2.1.

Any well known hydraulic oil with viscosity between 15-70 cSt at 40°C can be used with RPU80, RPU160 and RPU300.

Use higher viscosity in warmer areas.

6

20220422N

www.Busse-Yachtshop.de email: info@busse-yachtshop.de