INSTALLATION
HOME AUTOMATION |
Installing Door / Window Sensors
Window / Door Sensor is used to monitor doors or windows that open and close. When these doors / windows are open or closed, the sensors will transmit a signal to the control panel to notify the user. These sensors consist of 2 parts, one is the transmitter, the other is the magnet.
Transmitter Magnet
| ZONE LED | DESCRIPTION |
| Off | Zone is not occupied by any control module |
|
|
|
| Flashes twice | That means a remote has occupied that zone. |
|
| THIS IS NOT A CONTROL MODULE, THEREFORE, SHOULD NOT BE |
|
| ERASED. |
|
|
|
| Flashes once | That zone is occupied by a control module. You may select this |
Before installing the sensor, remove the battery isolator by pulling out the yellow tab. Once the isolator is removed, the control panel will announce the sensor's status, such as "Zone 1 Sensor 1 Triggered", and corresponding zone LED will flash and buzzer will beep. If the magnetic contact is closed, the beeping will stop.
Note:
-Both Window/Door Sensors have been programmed at the factory. They are Zone 1 Sensor 1 and Zone 2 Sensor 1. Trigger the sensor and listen to the announcement to determine which one is zone 1 and which is zone 2.
Mounting the Sensor
The transmitters should be mounted on the door frame or window frame by double sided tape. The magnet should be mounted on the door or window by either double sided tape or screws. Make sure the magnet is aligned with the red marking on the transmitter. If the surface of the frame is flat enough, double- sided foam tape is sufficient, otherwise, it is recommended to screw the mounting plate to the frame, then apply double sided tape. After mounting the sensor, if the AAA+ logo is inverted, remove the front cover and rotate it so the AAA+ logo is in the upright position.
Magnet | Magnet | |
"Red Marking" | "Red Marking" | |
Sensor | ||
Sensor |
Magnet on the left | Magnet on the right | Mounting plate | |
|
| and screws | foam tape |
|
| (optional) |
|
Testing:
After mounting the sensor, test the sensor by opening and closing the door or window. Open the door or window will result in the followng:
1.Voice announcement - Announce the triggered zone and sensor
2.Beeping - The number of beep represents the zone number
3.Zone LED flashing - Number of flash represents the sensor number.
| zone to erase this control module. |
|
|
Flashes once, | That means this zone is occupied by a remote AND a control module. |
then twice | You may select this zone to erase the control module. |
**Table F: Zone LED status for erasing control module.
Part 2 Erase communication from Control Panel to Control Module
Step | Keys | Function | Description | Note |
|
|
|
|
|
1 | Remove the | Enter program- | Enter master | 3 beeps for valid |
| control module | ming mode | password to | password. 1 long |
| from the |
| programming | beep for invalid |
| electrical outlet |
| mode | password. |
|
|
|
|
|
2 | Press and hold | To erase the |
| Control module LED |
| the learn button | memory of the |
| will flash rapidly |
| on the control | control module |
| indicating all the |
| module while |
|
| memory is erased. |
| plugging in the |
|
| You may now |
| control module |
|
| release the learn |
| to an electrical |
|
| button. |
| outlet. |
|
|
|
|
|
|
|
|
Once the memory of the control module is erased, all of its memory is cleared. If you have other remotes / control panels controlling this control module, you need to