SkyLink am-100 manual Communication, Alert Zone Bypass Zone, Receiving the Emergency Call

Models: am-100

1 28
Download 28 pages 8.83 Kb
Page 25
Image 25
COMMUNICATION

ADVANCED PROGRAMMING

COMMUNICATION

Receiving the Emergency Call

 

DISABLE

ENABLE

®

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO MUTE

AUTO MUTE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone 1

Button [1]

Button [6]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone 2

Button [2]

Button [7]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone 3

Button [3]

Button [8]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone 4

Button [4]

Button [9]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone 5

Button [5]

Button [0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This row : Buttons to Disable Auto Mute

Zone LED : Flash

This row : Buttons to Enable Auto Mute

Zone LED : ON

If you are on the list as one of the recipients of the emergency call, you should read the following instructions carefully. You should also notify all the persons you will be calling so they know how to react when they receive the emergency call.

The control panel will call you when there are emergencies such as break-ins, smoke, fire events, or someone at home needs assistance.

1.When the phone rings at the calling location, the person who answers the phone will hear a message related to the emergency events, such as “System Panic”, or “Zone 1 Sensor 1 Triggered” etc. This message may be repeated several times depending on how it was programmed.

Alert Zone (Bypass Zone)

As explained earlier, the control panel can operate in 2 different modes, 1) Alert Mode, 2) Alarm Mode. In alarm mode, when a sensor is triggered, the control panel will either give a 30 seconds entry delay, or siren will sound immediately (with instant alarm). However, there are sensors that you do not want to trigger the alarm when the system is armed. Such as an outdoor sensor, or any other sensors that you only want to give you alert notification. Under such circum- stances, zone(s) can be programed to react only when the control panel is in alert mode, these zones will be automatically bypassed when the control panel is in alarm mode. These zones can also be considered as "Bypass zones".

It is recommend to enable alert zone if:

-You do not consider the sensors in that zone an emergency

-Sensors in that zone are located outdoors

-When nobody is home, you do not want to know the status of the sensor(s) in that zone

Factory Default: This feature was disabled for all zones at the factory.

2.After the message has been repeated for

a certain number of times, the control panel will ask for a valid password, you will hear “Enter Password”.

3.Enter the 4-digit password to have access to the control panel. If a valid password is accepted, you will hear “Password Accepted”, otherwise, you will hear “Password Failure”.

4.After entering the correct password, you can follow the “Phone Command” instruc- tions to perform the required tasks, such as disarm, turn on / off devices or check the system status etc. For further information of how to control the system remotely, please refer to the next section, "Remote Operation by Telephone".

Receiving the Emergency CallZone 1

Sensor 1

Triggered

Enter

Password

-Arm

-Disarm

-Check status

-Control lighting etc. -Disconnect

30

23

Page 25
Image 25
SkyLink am-100 manual Communication, Alert Zone Bypass Zone, Receiving the Emergency Call, Advanced Programming