SkyLink am-100 manual Operation, Home Automation, Alert Mode Examples

Models: am-100

1 28
Download 28 pages 8.83 Kb
Page 17
Image 17
OPERATION

HOME AUTOMATION

Part 1 Learn signal from Control Module to Control Panel

Step

Keys

 

Function

Description

Note

1

[PROG]

 

Enter Program-

Enter master

3 beeps for valid

 

[MPIN]

 

ming mode

password to

password. 1 long beep

 

 

 

 

 

programming

for invalid password.

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

2

[4]

 

 

Select learn

 

After [4] is entered, some

 

 

 

 

control module

 

zone LEDs will flash or

 

 

 

 

programming

 

stay off. The zone LEDs

 

 

 

 

 

 

represent whether that

 

 

 

 

 

 

zone is already occupied

 

 

 

 

 

 

by another control

 

 

 

 

 

 

module.**See Table E.

 

 

 

 

 

 

3

[1] to [5]

 

Select control

Select the

After you have selected

 

 

 

 

module location

location [1], [2],

the control module location,

 

 

 

 

(Max. 5 control

[3], [4], or [5].

that zone LED will be on.

 

 

 

 

modules)

 

 

 

 

 

 

 

4

Activate the

Send signal

Once the signal

You will hear

 

control module

from control

is transmitted to

[Device X Accepted],

 

by pressing its

module to

the Control Panel,

where “X” is the control

 

learn button

control panel.

that signal will be

module location.

 

once quickly.

 

stored.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONE LED

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

Off

 

 

Zone is not occupied by any control module

 

 

 

 

 

 

 

Flashes once

 

This zone is occupied by another control module. Programming

 

 

 

another remote to this zone will overwrite the previous control

 

 

 

module.

 

 

 

 

 

 

 

 

 

Flashes twice

 

This zone is occupied by a remote. You can still program a control

 

 

 

module to this zone, and it will not overwrite the remote you have in

 

 

 

this zone.

 

 

 

 

 

 

 

 

 

Flashes once,

 

This zone is occupied by a remote AND a control module. If you

then twice

 

program another control module to this zone, it will overwrite the

 

 

 

previous control module, but not the remote.

 

 

 

 

 

 

 

**Table E: Zone LED status for learning control module.

38

OPERATION

The Control Panel is always in one of the 2 operating modes:

1.Alert Mode - When the system is not armed (ARM LED off), it is in alert mode.

2.Alarm Mode - When the system is armed (ARM LED on), it is in alarm mode.

Alert Mode

The Control Panel will be in alert mode automatically if the system is not armed. Alert mode allows users inside the premises to know what sensor is triggered. It is intended to be used when someone stays inside the premises.

In alert mode, the control panel will give you notification of the triggered sensor(s) by voice announcement, unique beeping and LED flashing.

1

Number of beeps

Zone of the triggered sensor

2

Number of flashes of zone LED

Sensor number of the triggered sensor

3

Voice announcement

Tells you the zone and locations of

 

 

the triggered sensor by human voice.

Note:

-Each zone can program up to 2 sensors. There are 5 zones, so up to 10 sensors can be programmed to the control panel. Please refer to page 34, "Sensor Location Selection Guide" for detail information.

Alert Mode Examples

Zone 1 Sensor 1

1.

3. Single flash

door open

Zone 1

Sensor 1

Triggered

2.Beep___Beep___ Alert ModeAlert Mode ExamplesManual backgroundManual background Beep___Beep .....Manual backgroundManual background

Zone 3 Sensor 2 window

1. Zone 3

3. Double flash

 

 

 

 

open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensor 2

 

 

 

 

 

 

Triggered

 

 

 

 

 

 

 

2.Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Beep Beep Beep___ Manual backgroundManual backgroundManual backgroundManual background

Beep Beep Beep___Manual backgroundManual background

Note:

-For Door / Window sensor, alert notification (beeping and LED flashing) will continue until the sensor is in closed position, i.e. closing the window or door.

-For Motion Sensor, the alert notification (beeping and LED flashing) will last for 15

seconds for every detected movement.