C
OMMAND

L

INE

I

NTERFACE

3-86

Command Mode
Line Configuration
Command Usage
When the logon attempt threshold is reached, the system
interface becomes silent for a specified amount of time before
allowing the next logon attempt. (Use the silent-time command
to set this interval.) When this threshold is reached for Telnet,
the Telnet logon interface shuts down.
This command applies to both the local console and Telnet
connections.
Example
To set the password threshold to five attempts, enter this
command:
Related Commands
silent-time (3-86)

silent-time

Use this command to set the amount of time the management
console is inaccessible after the number of unsuccessful logon
attempts exceeds the threshold set by the password-thresh
command. Use the no form to remove the silent time value.
Syntax
silent-time seconds
no silent-time
seconds - The number of seconds to disable console
response. (Range: 0-65535; 0: no silent-time)
Console(config-line)#password-thresh 5
Console(config-line)#
b_mgmt.book Page 86 Tuesday, July 8, 2003 5:24 PM