Wiring ( continued )

The Power Supply Cable (for Power Supply Connector of Power Block) is a bypass cable which can be used when

the Power Block is positioned next to the SI Unit.

NOTE

Mount a Waterproof Cap on unused Power Supply Connector. The proper use of Waterproof Cap can achieve IP67 Enclosure. (Tightening torque : 0.1Nm for M12) For Waterproof Cap, refer to "Option" (page 32) in this manual.

Display

Output Block

Display

 

Description

0,1

Lights up

Output corresponding to the number is ON.

 

 

Off

Output corresponding to the number is OFF.

 

 

 

 

Power Block

Display

 

Description

PWR

Lights up

External power supply is ON.

 

 

Off

External power supply is OFF.

 

 

 

 

PWR

Option

Ethernet Communication Cable

For details, refer to subsection "Wiring" (page 12) in section "SI Unit" in this manual.

How to order

EX9-AC 020 EN - PSRJ

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable length ( L )

 

 

 

 

 

 

Connector specification

 

 

020

2 [m]

 

 

 

 

 

 

 

PSRJ

M12 plug ( straight ) RJ45 connector

Power Supply Cable

For details, refer to subsection "Wiring" (page 13) of section "SI Unit" in this manual.

How to order

EX500-AP 050 - S

 

 

 

 

 

 

 

 

 

 

 

Cable length (L)

 

 

 

 

Connector specification

 

 

010

1 [m]

 

 

 

 

 

S

Straight

 

050

5 [m]

 

 

 

 

 

 

 

 

 

Spare Fuse (for Input Block)

How to order

EX9-FU 05

Rating ( A )

05 0.5A

Output Cable

For details, refer to subsection "Wiring" (page 26) of section "EX9 series Output Block/Power Block" in this manual.

How to order

EX9-AC 010 -7

Cable length ( L )

010

1 [m]

030

3 [m]

Power Supply Cable (for power input connector of Power Block)

For details, refer to subsection "Wiring" (page 29) of section "EX9 series Output

Block/Power Block" in this manual.

How to order

EX9-AC 010 -1

Cable length ( L )

010

1 [m]

030

3 [m]

050

5 [m]

6Power Supply Cable (for power supply connector of Power Block)

For details, refer to subsection "Wiring" (page 29) of section "EX9 series Output

Block/Power Block" in this manual.

How to order

EX9-AC 002 -3

Cable length (L)

002 0.2 [m]

30

31

Page 17
Image 17
SMC Networks EX9-AC -1, EX500-AP -S, EX250-SEN1, EX9-AC020EN-PSRJ, EX9-AC002-3, EX9-OET1 EX9-OEP1, EX9-AC -7 Display, Option