Smeg CSA150X-6 manual Gas connection, Instructions for the Installer

Models: CSA150X-6

1 40
Download 40 pages 33.11 Kb
Page 6
Image 6
Gas connection

Instructions for the Installer

Overall dimensions: location of gas and electrical connection points (all measures in mm).

 

A

110

 

B

760

 

C

170

 

D

150

2.3

Gas connection

 

This appliance is suitable for installation with Natural Gas or ULPG (propane). Refer to page 13 for the relevant burner pressure and appropriate injector sizes. When the appliance is to be connected to Natural Gas then the pressure regulator supplied must be fitted to the gas inlet. A test point (for checking the gas pressure) is supplied either with the regulator or as a separate fitting in the case of LPG (propane) appliances.

Connection of the appliance to the gas supply must be in accordance with the requirements of AS5601. A ½” BSP connector at the inlet is recommended and the gas supply line to the appliance must be of adequate length to allow sufficient withdrawal of appliance for service or disconnection and be:

1)annealed copper pipe or;

2)Flexible hose according to AS/NZ1869 & be at least Class “B”, 10 mm diameter, max length 100 mm.

The cooker must be installed with provision to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply.

Before the cooker is operated make certain all relevant

8

Page 6
Image 6
Smeg CSA150X-6 manual Gas connection, Instructions for the Installer