Smeg CSA150X-6 manual Final Operations, Adjusting the minimum setting for natural gas

Models: CSA150X-6

1 40
Download 40 pages 33.11 Kb
Page 12
Image 12
4.FINAL OPERATIONS

Instructions for the Installer

4.FINAL OPERATIONS

After changing the nozzles, put the pan stands, the burner caps and flame diffuser rings back in place.

After adjusting for use of a gas other than the gas used for testing the appliance, replace the gas setting label on the appliance with the label for the new gas. The label is supplied in the bag with the nozzles.

4.1 Adjusting the minimum setting for natural gas

Light the burner and turn it to the minimum setting 4.1 Adjusting the minimum setting for natural gas Remove the gas tap knob and adjust the regulator screw inside or beside the tap rod (depending on the model) until an even minimum flame is obtained. Put the knob back in place and check the stability of the burner flame (the flame must not go out when the knob is turned quickly from the maximum to the minimum setting). Repeat the operation on all the gas taps.

4.2 Adjusting the minimum for bottled gas

To adjust the minimum level when using bottled gas, the adjuster screw inside or beside the tap rod must be turned fully clockwise (depending on the models).

The diameters of the bypasses for each individual burner are stated in point "3.2 Burner and Nozzle Data Tables".

4.3Fitting the rear splash-back

Place the splash-back on the hob, aligning the holes A with the holes B.

Fix the splash-back to the hob by tightening the screws C.

14

Page 12
Image 12
Smeg CSA150X-6 Final Operations, Adjusting the minimum setting for natural gas, Adjusting the minimum for bottled gas