12 SCREEN DISPLAYED ANOMALIES (USER)
The machine is capable of signaling a series of malfunctions on the display.
If the problem persists after having turned the machine off and then on again, act as indicated below:
E1 | Boiler sensor malfunction | |
|
| |
E2 | Tank sensor malfunction | |
|
| |
E3 | Water loading timeout ( the water loading duration | |
has exceeded the set time ) | ||
| ||
|
| |
| Draining anomaly. At the end of the draining phase | |
| the CPU still detects water in the Tank. This may | |
E6 | be due to: Drain pump malfunction (if present), | |
drain tube blockage, Tank Pressostat malfunction, | ||
| ||
| drain cycle time set too low, overflow inserted in | |
| the Tank | |
|
| |
E7 | 30 minute Tank timeout | |
|
| |
E8 | 15 minute boiler timeout | |
|
|
Consult with the Technical Assistance Service
Consult with the Technical Assistance Service
Verify that the water supply faucet is open, the dynamic pressure of the supply and the cleanliness of the water input filter. If the problem persists consult with the Technical Assistance Service.
Verify the cleanliness of the filters and that the drain tube is not blocked, bent or crushed. Verify that the drain pump is not blocked by a foreign object: act as indicated in point “10.2 Periodic Checks”.
If the problem persists consult with the Technical Assistance Service.
Consult with the Technical Assistance Service