Equaliser

Appendix

Equaliser

This is a four band equaliser that can be switched between two different sets of curves; one based on SSL’s ‘02’ (‘Brown Knob’) EQ and the other based on the latest version of the classic ‘242’ E Series (‘Black Knob’) EQ. High and low pass filters are also available.

HF Band controls:

 

Frequency

Variable from 1.5kHz to 16kHz

Gain

Variable between ±15dB (‘02’)

 

Variable between ±18dB (‘242’)

‘Q’ (on ‘BELL’ setting)

0.8 (‘02’)

 

1.3 (‘242’)

HMF Band controls:

 

Frequency

Variable from 600Hz to 7kHz

Gain

Variable between ±15dB (‘02’)

 

Variable between ±18dB (‘242’)

‘Q’

Variable from 0.5 to 2.5 (‘02’)

 

Variable from 0.5 to 4 (‘242’)

LMF Band controls:

 

Frequency

Variable from 200Hz to 2.5kHz

Gain

Variable between ±15dB (‘02’)

 

Variable between ±18dB (‘242’)

‘Q’

Variable from 0.5 to 2.5 (‘02’)

 

Variable from 0.5 to 4 (‘242’)

LF Band controls:

 

Frequency

Variable from 30Hz to 450Hz

Gain

Variable between ±15dB (‘02’)

 

Variable between ±18dB (‘242’)

‘Q’ (on ‘BELL’ setting)

0.8 (‘02’)

 

1.3 (‘242’)

Filter controls:

 

Low Pass Frequency

3kHz to 16kHz (–3dB Point)

Low Pass Slope

12dB/octave

High Pass Frequency

20Hz to 350Hz (–3dB Point)

High Pass Slope

12dB/octave (‘02’)

 

18dB/octave (’242’)

Measurement Conditions

Signal applied to Line Input and measured at Output. EQ switched In. All EQ controls set centre as appropriate.

THD + N

< 0.05% at +20dBu 1kHz

Frequency Response

±0.25dB from 20Hz to 20kHz

Output Headroom

> +26dBu at onset of clipping

Noise

< –73dBu