English

Self-diagnosis display

Your camcorder has a self-diagnosis display function.

This function displays the current condition of your camcorder as a 5-digit code (a combination of a letter and figures) in the viewfinder or on the LCD screen. If a 5-digit code is displayed, check the following code chart. The last two digits (indicated by ss) will differ depending on the state of your camcorder.

Viewfinder or LCD screen

C:21:00

Self-diagnosis display

 

•C:ss:ss

 

You can service your camcorder

 

yourself.

 

•E:ss:ss

 

Contact your Sony dealer.

 

 

Five-digit display

Cause and/or Corrective Actions

C:04:ss

• You are using a battery pack that is not an “InfoLITHIUM”

 

battery pack.

 

c Use an “InfoLITHIUM” battery pack (p. 15).

C:21:ss

• Moisture condensation has occurred.

 

c Remove the cassette and leave your camcorder for at least 1

 

hour to acclimatize (p. 189).

C:22:ss

• The video heads are dirty.

 

c Clean the heads using the Sony DVM12CLD cleaning cassette

 

(not supplied) (p. 190).

C:31:ss

C:32:ss

A malfunction other than the above that you can service has occurred.

c Remove the cassette and insert it again, then operate your camcorder.

c Disconnect the mains lead of the AC adaptor or remove the battery pack. After reconnecting the power source, operate your camcorder.

E:61:ss

E:62:ss

• A malfunction that you cannot service has occurred.

cContact your Sony dealer or local authorized Sony service facility and inform them of the 5-digit code. (example: E:61:10)

If you are unable to rectify the problem even if you try corrective actions a few times, contact your Sony dealer or local authorized Sony service facility.

176