TIME CODE [Time code]: Settings related to the time code

Description of settings

 

generator

 

 

 

 

 

 

VITC [> VITC]: Determine whether to record the internally

OFF [>> OFF]: Do not record the internally generated time

 

generated time code as VITC.

code as VITC. (VITC present in the input video signal is

 

 

 

 

recorded unchanged.)

 

 

 

 

*ON [>> ON]: Record the internally generated time code as

 

 

 

 

VITC.

 

 

 

 

 

TCG REGEN [>TCG regen]: Select the signal to be

*TC & UB [>> TC & UB]: Both the time code and user bits are

 

regenerated when the time code generator is in the

regenerated.

 

regeneration mode (i.e., when the TC MODE menu item is

TC [>> TC]: Only the time code is regenerated.

 

set to INT REGEN or EXT REGEN).

UB [>> UB]: Only the user bits are regenerated.

 

 

 

 

 

UB BINARY GP. [> Binary Gp.]: Select the user bit binary

*000: NOT SPECIFIED [>> 000]: Character set not specified

 

group flag of the time code generator.

001: ISO CHARACTER [>> 001]: 8-bit characters conforming

 

 

 

 

to ISO 646 and ISO 2022

 

Note

 

 

010: UNASSIGNED-1 [>> 010]: Undefined

 

When the TC MODE menu item is set to EXT REGEN, the

011: UNASSIGNED-2 [>> 011]: Undefined

 

100: UNASSIGNED-3 [>> 100]: Undefined

 

user-bit binary group flag setting follows the setting on the time

 

code input to this unit.

101: PAGE/LINE [>> 101]: Multiplex

 

110: UNASSIGNED-4 [>> 110]: Undefined

 

 

 

 

 

 

 

 

111: UNASSIGNED-5 [>> 111]: Undefined

 

 

 

 

 

VITC POS SEL-1 [>VITC pos-1]: Select a line to insert the

(For DSR-1800A)

 

VITC in.

12 LINE [>> 12 line] to 20 LINE [>> 20 line]: Select any line

 

 

 

 

from 12 to 20.

 

Note

 

 

Factory default setting: 16 LINE [>> 16 line]

 

You can insert the VITC signal in two places. To insert it in two

 

 

 

 

(For DSR-1800AP)

 

places, set both this item and also VITC POS SEL-2.

Select a line to insert the VITC in.

 

 

 

 

9 LINE [>> 9 line] to 22 LINE [>> 22 line]: Select any line

 

 

 

 

from 9 to 22.

 

 

 

 

Factory default setting: 19 LINE [>> 19 line]

 

 

 

 

VITC POS SEL-2 [>VITC pos-2]: Select a line to insert the

(For DSR-1800A)

 

VITC in.

12 LINE [>> 12 line] to 20 LINE [>> 20 line]: Select any line

 

 

 

 

from 12 to 20.

 

Note

 

 

Factory default setting: 18 LINE [>> 18 line]

 

You can insert the VITC signal in two places. To insert it in two

 

 

 

 

(For DSR-1800AP)

 

places, set both this item and also VITC POS SEL-1.

Select a line to insert the VITC in.

 

 

 

 

9 LINE [>> 9 line] to 22 LINE [>> 22 line]: Select any line

 

 

 

 

from 9 to 22.

 

 

 

 

Factory default setting: 21 LINE [>> 21 line]

 

 

 

 

VITC OUTPUT [>VITC out]: Select the time code to be output

OFF [>> OFF]: Do not output VITC.

 

as VITC.

TC [>> TC]: Output TC after converting it into VITC.

 

 

 

 

*VITC [>> VITC]: Output VITC.

 

 

 

 

EE OUT PHASE [>EE out]: Determine the output phase for

*MUTE [>>mute]: Mute the output.

 

the LTC signal output from the TIME CODE OUT

THROUGH [>> through]: Output the time code input to the

 

connector when recording time code and in STOP REC

TIME CODE IN connector as it is. (See example

 

mode (forced EE mode).

configuration on page 73.)

 

 

 

 

VIDEO INPUT PHASE [>> V input]: Output the time code

 

 

 

 

with the same phase as the input video signal phase.

 

 

 

 

(See example configuration on page 73.)

 

 

 

 

VIDEO OUTPUT PHASE [>> V output]: Output the time code

 

 

 

 

with the same phase as the output video signal phase.

 

 

 

 

(See example configuration on page 74.)

 

 

 

 

MUTE IN SRCH [>Mute in SR]: Select whether to mute the

OFF [>> OFF]: Do not mute.

 

output from the TIME CODE OUT connector in search

*ON [>> ON]: Mute.

 

(jog/shuttle) mode.

 

 

 

 

 

 

Settings Menu 4 Chapter

Menu Contents 67