2. Pass-fail judgment of the optical device (KEM-460AAA)

Perform pass-fail judgment to judge whether the repair of the optical device (KEM-460AAA) is necessary.

2-1. Flow of drive section check

Confirm whether

BD (BLX-104) can be reproduced

YES

Confirm whether DVD (HLX-513)/ CD (HLX-A1) can be reproduced

NO

NO

Confirm whether the drive voltage is the following values CN301 pin 2 : 12 V CN301 pin 6 : 5 V

YES

Confirm OP FFC cable (Part No. 1-837-494-11) and SPDL FFC cable (Part No. 1-837-495-11), and replace it when it has been damaged

Then, confirm whether

this set operates normally

YES

OK

NO

Confirm PS301 to

PS304 on the MB-134

 

 

board, and replace it

 

when it has been

 

damaged

NO

Confirm whether the

optical device IOP

 

 

is normal in the

 

 

service mode

 

 

(Refer to “2-2. Flow

 

 

of optical device

 

 

IOP check”)

 

 

 

 

 

 

 

 

 

NO

Repalece the optical device (KEM-460AAA)

(Refer to “3. Optical

device (KEM-460AAA) replacement”)

Note: Refer to “2-12. OPTICAL DEVICE (KEM-460AAA), WIRE (FLAT TYPE)” (page 17) about how to remove the FFC HOLDER (REAR).

2-2. Flow of optical device IOP check

Turn the power on, and change function to “BD/DVD”

Press the buttons on

the remote commander in order of [RETURN], [0], [2], [1] [SUBTITLE], and enter the service mode

Press the buttons on

the remote commander in order of [8], [7], [3], [ENTER], and the dIOP value is displayed

Confirm whether

value is the specification value

Specification value:

BD: 6 mA

DVD/CD: 9 mA

YES

OK

NO

Repalece the optical device (Refer to “3. Optical device (KEM-460AA) replacement”)