SECTION 3

TEST MODE

COLD RESET

The cold reset clears data except BD/DVD data stored in the RAM to initial conditions. Execute this mode when returning the set to the customers.

Procedure:

1.Press the [?/1] button to turn the power on.

2.Press the [x] and [VOLUME –] buttons simultaneously and hold down (around 5 seconds).

3.The message “COLD RESET” appears on fluorescent indica- tor tube, then becomes standby states.

DEMO MODE

This mode let you lock the disc tray. When this mode is activated, the disc will not eject when the [Z] button is pressed. The message “LOCKED” will be displayed on the fluorescent indicator tube.

Procedure:

1.Press the [?/1] button to turn the power on.

2.Press the [FUNCTION] button to select the “BD/DVD”.

3.Press the [x] and [Z] buttons simultaneously and hold down until “DEMO ON” or “DEMO OFF” displayed on the fluores- cent indicator tube (around 5 seconds).

S-AIR ID SETTING CHANGE

Procedure:

1.Press the [?/1] button to turn the power on.

2.Press the [FUNCTION] and [VOLUME +] buttons simultane- ously and hold down (around 5 seconds).

3.S-AIR ID setting is changed (A → B → C → A...).

PANEL TEST

Procedure:

1.Press the [?/1] button to turn the power on.

2.Press button in order of the [RETURN] → [0] → [0] → [1] → [SUBTITLE] on the remote commander (Make the interval when each button is pressed within two seconds).

3.All segments in fluorescent indicator tube are lighted up. And half segments in fluorescent indicator tube are lighted up, oth- ers half segments in fluorescent indicator tube are lighted up, then LEDs and all segments in fluorescent indicator tube are lighted up. This operation is repeated.

4.When all segments in fluorescent indicator tube are lighted up in the state of step 3, press the [VOLUME +] button on the remote commander and model information is displayed on the fluorescent indicator tube.

Each time the [VOLUME +] button on the remote commander is pressed, the display changes from destination information, STR version, SYS version, UI version, BDLIB version, ST version, TA version, DSP version, TM version, CEC version, SAIR version, PF version in this order, and returns to the mod- el information display.

Each time the [VOLUME –] button on the remote commander is pressed, the version and date are switched.

5.In the state of step 3, press the [FUNCTION] button on the remote commander and “K 0” is displayed on the fluorescent indicator tube.

“K 0” value increases whenever a button on the set is pressed. However, once a button has been pressed, it is no longed taken into account.

All buttons on the set are pressed, “OK” and “K 7” are alter- nately displayed on the fluorescent indicator tube.

6.To release from this mode, press the [?/1] button.

AMP TEST

Procedure:

1.Press the [?/1] button to turn the power on.

2.Press button in order of the [RETURN] → [0] → [1] → [1] → [SUBTITLE] on the remote commander (Make the interval when each button is pressed within two seconds).

3.The message “MEASURE” appears on the fluorescent indica- tor tube and enter the AMP test mode.

4.Press the [BLUE] button on the remote commander, the state of D.C.A.C. microphone is displayed on the fluorescent indica- tor tube.

*** @@ $$$

***: Either of “IN”/“NON” is displayed by the state of detection of the microphone.

@@

: Either of “OK”/“NG” is displayed by the state of

 

digital audio data input.

$$$

: Microphone input audio data A/D value (0 – 255).

5.Press the [MUTING] button on the remote commander, “VOL N” (The change in the volume is usual)/“VOL MSM” (The change in the volume is a switch of MIN/1/20/MAX) can be switched.

6.Press the [SUBTITLE] button on the remote commander, the message “VACS ON” or “VACS OFF” appears on the fluores- cent indicator tube and thus the VACS on/off are changed.

7.To release from this mode, press the [?/1] button.

BD SERVICE MODE

Note: The operation in this mode must use a remote commander.

Setting method of the BD service mode:

1.Press the [?/1] button to turn the power on.

2.Press button in order of the [RETURN] → [0] → [2] → [1] → [SUBTITLE] on the remote commander. (Make the interval when each button is pressed within two seconds)

3.Enter the BD service mode.

1.Main Functions

• ErrorLog display

Display the error log. Displayed contents can also be saved in an USB memory device.

• Diag

Performs unit test of devices installed on the board.

• Factory Initialize

Restores the set to its factory settings.

• Network

Checks the wired network connection.

• Version Up (version update) Not used.

• System Information

Displays the system information of the set.

Displays information such as the software version, drive infor- mation, etc.

• EMC Test Mode Not used.

• Drive

Write drive OP data and check drive.