HCD-PX333

MD SECITON

1. PRECAUTIONS FOR USE OF TEST MODE

As operations related to loading will be performed regardless of the test mode operations being performed, be sure to check that the disc is stopped before setting and removing it.

Even if the Z (MD) button is pressed while the disc is rotating during continuous playback, continuous recording, etc., the disc will not stop rotating.

Therefore, it will be ejected while rotating.

Be sure to press the Z (MD) button after pressing the MENU/NO “R” button and the rotation of disc is stopped.

1-1. Recording laser emission mode and operating buttons

Continuous recording mode (CREC 2MODE)

Laser power check mode (LDPWR CHECK)

Laser power adjustment mode (LDPWR ADJUST)

Comparison with initial Iop value written in nonvolatile memory (Iop Compare)

Write current Iop value in read nonvolatile memory using microprocessor (Iop NV Save)

Traverse (MO) check (EF MO CHECK)

Traverse (MO) adjustment (EF MO ADJUST)

When pressing the [REC/REC IT] button.

2. SETTING THE TEST MODE

The following are two methods of entering the test mode.

Procedure 1: 1. Press the ?/1 button to turn the power on.

2.Press the [FUNCTION] button to set the MD function.

3.Press three buttons of M > TUNING + , [REC MODE], and . m (MD) simultaneously.

When the test mode is set, “[Check]” will be displayed. Pressing the . “R” or > “R” button between the following three groups; ···Tt [Check] Tt [Service] Tt [Develop] Tt ···.

Procedure 2: 1. Press the ?/1 button to turn the power on.

2.Press the [FUNCTION] button to set the MD function.

3.Press three buttons of x (CD) , [REC MODE], and M > (MD) simultaneously.

When the test mode is set, “AUTO CHECK” (C01) will be displayed. By setting the test mode using this method, only the “Check” group of procedure1 can be executed.

Note: Do not use the test mode in the [Develop] group. If used, the unit may not operate normally.

If the [Develop] group is set accidentally, press the

MENU/NO “R”

button immediately to exit the [Develop] group.

3. RELEASING THE TEST MODE

Press the [REPEAT STEREO/MONO] button to display “Initialize”, then release the MD test mode.

4.BASIC OPERATIONS OF THE TEST MODE

All operations are performed using the . “R” , > “R” The functions of these buttons are as follows.

,

ENTER/YES “R”

and

MENU/NO “R”

.

 

 

Function name

Function

 

 

 

 

 

 

buttons

Changes parameters and modes

 

. “R”

,

> “R”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTER/YES “R”

button

Proceeds onto the next step. Finalizes input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Returns to previous step. Stops operations

 

MENU/NO “R”

button

 

 

 

 

 

 

 

 

32

Page 32
Image 32
Sony HCD-PX333 specifications MD Seciton Precautions for USE of Test Mode, Setting the Test Mode, Releasing the Test Mode