HCD-PX333
14. ERROR RATE CHECK
14-1. CD Error Rate Check
Procedure:
1.Load the check disc
2.Press the . “R” or > “R” button and display “CPLAY2 MODE” (C36).
3.Press the ENTER/YES “R” button twice and display “CPLAY2 MID”.
4.The display changes to “C = AD = )”.
5.Check that the C1 error rate is below 20.
6.Press the MENU/NO “R” button to stop playback, then press the Z (MD) button and take out the check disc.
Procedure:
1.Load the
2.Press the . “R” or > “R” button to display “CPLAY2 MODE” (C36).
3.Press the ENTER/YES “R” button to display “CPLAY2MID”.
4.The display changes to “C1 = AD = )”.
5.If the C1 error rate is below 20, check that ADER is 00.
6.Press the MENU/NO “R” button to stop playback, then press the Z (MD) button and take out the disc.
15. FOCUS BIAS CHECK
Change the focus bias and check the focus tolerance amount.
Procedure:
1.Load the
2.Press the . “R” or > “R” button to display “CPLAY2 MODE” (C36).
3.Press the ENTER/YES “R” button twice to display “CPLAY2 MID”.
4.Press the MENU/NO “R” button when “C1 = AD = )” is displayed.
5.Press the . “R” or > “R” button to display “FBIAS CHECK” (C16).
6.Press the ENTER/YES “R” button to display “ / c = ”. The first four digits indicate the C1 error rate, the two digits after “/ ” indicate ADER, and the 2 digits after “c =” indicate the focus bias value.
| Check that the C1 error is below 20 and ADER is below 2. |
| ||||
7. | Press the |
| button and display “ | / | b = | |
ENTER/YES “R” | ||||||
| ”. |
|
| |||
| Check that the C1 error is below 100 and ADER is below 2. | |||||
8. | Press the |
| button and display “ | / | a = | |
ENTER/YES “R” | ||||||
| ”. |
|
| |||
| Check that the C1 error is below 100 and ADER is below 2 |
9.Press the MENU/NO “R” button, then press the Z (MD) button and take out the disc.
Note: If the C1 error and ADER are above other than the specified value at points a (step 8. in the above) or b (step 7. in the above), the focus bias adjustment may not have been carried out prop- erly. Adjust perform the beginning again.
16. AUTO GAIN CONTROL OUTPUT LEVEL ADJUSTMENT
Be sure to perform this adjustment when the optical
If the adjustment results becomes “Adjust NG!”, the optical pick- up may be faulty or the servo system circuits may be abnormal.
16-1. CD Auto Gain Control Output Level Adjustment
Procedure:
1.Load the check disc
2.Press the . m“R” or M >“R” button to display “AG Set (CD)” (C11).
3.When the ENTER/YES “R” button is pressed, the adjustment will be performed automatically.
“Complete!” will then be displayed momentarily when the value is recorded in the
4.Press the Z (MD) button and take out the check disc.
16-2. MO Auto Gain Control Output Level Adjustment
Procedure:
1.Load the test disc
2.Press the .“R” or >“R” button to display “AG Set (MO)” (C10).
3.When the ENTER/YES “R” button is pressed, the adjustment will be performed automatically.
“Complete!” will then be displayed momentarily when the value is recorded in the
4.Press the Z (MD) button and take out the test disc.
46