HCD-PX333
5. SELECTING THE TEST MODE
There are 26 types of test modes as shown below. The groups can be switched by pressing the | . “R” | or | > “R” | button. After selecting | ||
the group to be used, press the |
| button. After setting a certain group, pressing the |
| or |
| button switches modes |
ENTER/YES “R” | . “R” | >“R” | ||||
shown below. |
|
|
|
| ||
Refer to “Group” in the table for details can be selected. |
|
|
|
|
All items used for servicing can be treated using group [Service]. So be carefully not to enter other groups by mistake.
Note: Do not use the test mode in the [Develop] group. If used, the unit may not operate normally.
If the [Develop] group is set accidentally, press the
MENU/NO “R”
button immediately to exit the [Develop] group.
Display | No. | Details | Mark | Group | |
Service | |||||
|
|
| Check | ||
AUTO CHECK | C01 | Automatic |
|
| |
Err Display | C02 | Error history display, clear |
|
| |
TEMP ADJUST | C03 | Temperature compensation offset adjustment |
|
| |
LDPWR ADJUST | C04 | Laser power adjustment |
|
| |
Iop Write | C05 | Iop data writing |
|
| |
Iop NV Save | C06 | Writes current Iop value in read nonvolatile memory using microprocessor |
|
| |
EF MO ADJUST | C07 | Traverse (MO) adjustment |
|
| |
EF CD ADJUST | C08 | Traverse (CD) adjustment |
|
| |
FBIAS ADJUST | C09 | Focus bias adjustment |
|
| |
AG Set (MO) | C10 | Auto gain output level adjustment (MO) |
|
| |
AG Set (CD) | C11 | Auto gain output level adjustment (CD) |
|
| |
TEMP CHECK | C12 | Temperature compensation offset check |
|
| |
LDPWR CHECK | C13 | Laser power check |
|
| |
EF MO CHECK | C14 | Traverse (MO) check |
|
| |
EF CD CHECK | C15 | Traverse (CD) check |
|
| |
FBIAS CHECK | C16 | Focus bias check |
|
| |
ScurveCHECK | C17 |
|
| ||
VERIFYMODE | C18 | Nonvolatile memory check |
|
| |
DETRK CHECK | C19 | Detrack check |
|
| |
0920 CHECK | C25 | Most circumference check |
|
| |
Iop Read | C26 | Iop data display |
|
| |
Iop Compare | C27 | Comparison with initial Iop value written in nonvolatile memory |
|
| |
ADJ CLEAR | C28 | Initialization of nonvolatile memory for adjustment values |
|
| |
INFORMATION | C31 | Display of microprocessor version, etc. |
|
| |
CPLAY2MODE | C36 | Continuous playback mode |
|
| |
CREC 2MODE | C37 | Continuous recording mode |
|
|
•For details of each adjustment mode, refer to “5. Electrical Adjustments”. For details of “Err Display”, refer to
•If a different mode has been selected by mistake, press the MENU/NO “R” button to release that mode.
•Modes with (⋅) in the Mark column are not used for servicing and therefore are not described in detail. If these modes are set acciden- tally, press the MENU/NO “R” button to release the mode immediately.
33