HCD-PX333

JIG FOR CHECKING BD (MD) BOARD WAVEFORM

The special jig (J-2501-196-A) is useful for checking the waveform of the BD (MD) board. The names of terminals and the checking items to be performed are shown as follows.

I+3V

: For measuring IOP (Check the deterioration of the optical pick-up laser)

IOP

: For measuring IOP (Check the deterioration of the optical pick-up laser)

GND : Ground

TE

: Tracking error signal (Traverse adjustment)

FE

: Focus error signal

VC

: Reference level for checking the signal

RF

: RF signal (Check jitter)

CN105

IOP

TE

VC

I+3V

GND

FE

RF

I+3V

IOP

GND

TE

FE

VC

RF

1

7

I+3V

 

IOP

 

GND

for

TE

MDM-7X2A

FE

 

VC

 

RF

 

9

Page 9
Image 9
Sony HCD-PX333 specifications JIG for Checking BD MD Board Waveform, Iop