8. Press the . “R” or >“R” button so that the waveform of
the oscilloscope becomes the specified value. |
|
(When the . “R” or > “R” button is pressed, the | of |
“EFB= ” changes and the waveform changes) In this adjustment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible.
(Write power traverse adjustment)
Traverse Waveform
A
VC
B
Specification A = B
9.Press the ENTER/YES “R” button, and save the adjustment results in the
10.“EFB =
The optical
11.Press the . “R” or > “R” button until the waveform of the oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible.
Traverse Waveform
A
VC
B
Specification A = B
12.Press the ENTER/YES “R” button, and save the adjustment results in the
Next “EF MO ADJUST” (C07) is displayed. The disc stops rotating automatically.
13.Press the Z (MD) button and take out the disc.
14.Load the check disc
15.Press the . “R” or > “R” button to display “EF CD ADJUST” (C08).
16.Press the ENTER/YES “R” button to display “EFB = CD”. Servo is imposed automatically.
17.Press the . “R” or >“R” button so that the waveform of the oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible.
Traverse Waveform
A
VC
B
Specification A = B
HCD-PX333
18.Press the ENTER/YES “R” button, display “EFB = SAVE” for a moment and save the adjustment results in the
Next “EF CD ADJUST” (C08) will be displayed.
19.Press the Z (MD) button and take out the check disc.
Adjustment Location: BD (MD) board (see page 47)
13.FOCUS BIAS ADJUSTMENT
Procedure:
1.Load the
2.Press the . “R” or > “R” button to display “CPLAY2 MODE” (C36).
3.Press the ENTER/YES “R” button to display “CPLAY2MID”.
4.Press the MENU/NO “R” button when “C = AD = )” is displayed.
5.Press the . “R” or > “R” button to display “FBIAS ADJUST” (C09).
6.Press the ENTER/YES “R” button to display “ / a = ”. The first four digits indicate the C1 error rate, the two digits after “/ ” indicate ADER, and the 2 digits after “a =” indicate the focus bias value.
7.Press the >“R” button and find the focus bias value at which the C1 error rate becomes about 200 (refer to Note 2).
8.Press the ENTER/YES “R” button to display “ / b = ”.
9.Press the .“R” button and find the focus bias value at which the C1 error rate becomes about 200.
10.Press the ENTER/YES “R” button to display “ / c = ”.
11.Check that the C1 error rate is below 20 and ADER is 00. Then
| press the | ENTER/YES “R” | button. | ||||
12. | If the “( | )” in “ - - | ( )” is above 20, press the |
| |||
ENTER/ | |||||||
|
|
| button. |
|
|
| |
| YES “R” |
|
|
|
| ||
| If below 20, press the |
|
| button and repeat the | |||
| MENU/NO “R” | ||||||
| adjustment from step 2. |
|
|
| |||
13. | Press thet | Z (MD) button and take out the disc. |
Note 1: The relation between the C1 error and focus bias is as shown in the following figure. Find points A and B in the following figure using the above adjustment. The focal point position C is auto- matically calculated from points A and B.
Note 2: As the C1 error rate changes, perform the adjustment using the average vale.
C1 error
about 200
Focus bias value
BCA
45