Chapter10 SetupMenus
Menu items in the range 200 to 299, relating to the remote control interface (Continued)
Item number | Item name |
| Settings | |||
|
|
|
|
|
| |
212 | VIDEO REMOTE |
| Make settings for control from | |||
| CONTROL SELECT |
| connector. | |||
| (Invalid in 24PsF or |
|
|
|
| |
| 23.98PsF mode) |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| ||
| 1 | IMAGE |
| Select whether to control the | ||
|
| ENHANCER |
| image enhancer. | ||
|
|
| down : Control the | |||
|
|
| up: Control the | |||
|
|
| u&d : Control both the | |||
|
|
|
|
| ||
| 2 | D2 SETUP |
| Select the menu item to be controlled by the SETUP dial on the | ||
|
|
|
| with the D2 button pressed. | ||
|
|
| setup : | |||
|
|
|
| REFERENCE LEVEL) | ||
|
|
| Black : Menu item 718 (SETUP LEVEL) | |||
|
|
|
| For details, see the description of menu item 718. | ||
|
|
|
|
| ||
|
|
|
| Note |
| |
|
|
|
| After changing the setting for this item, power off this unit or | ||
|
|
|
| power it on again. | ||
|
|
|
|
|
|
|
|
| Menu items in the range 300 to 399, relating to editing operations | ||||
|
|
|
|
|
|
|
Item number | Item name |
| Settings | |||
|
|
|
|
|
|
|
301 | VAR SPEED RANGE FOR |
| Select the playback speed range when carrying out playback in variable speed | |||
| SYNCHRONIZATION |
| mode from a remote control unit connected to the | |||
|
|
|
| or | ||
|
|
|
| |||
|
|
|
| speed for Digital Betacam, MPEG IMX tapes. | ||
|
|
|
| ˜2.45 : | ||
|
|
|
| normal speed for Digital Betacam and MPEG IMX tapes. | ||
|
|
|
|
|
|
|
302 | CAPSTAN |
| In 59.94i, 29.97PsF mode | |||
| DIRECTION |
| When the function menu item CAPSTN is set to 4F, select whether the capstan | |||
| (Invalid in 24PsF or |
| servo should lock by accelerating or decelerating. | |||
| 23.98PsF mode) |
| DECEL : Lock by decelerating. | |||
|
|
|
| ACCEL: Lock by accelerating. | ||
|
|
|
|
|
|
|
|
|
|
| In 50i, 25PsF mode | ||
|
|
|
| When the function menu item CAPSTN is set to 4F or 8F, select whether the | ||
|
|
|
| capstan servo should lock by accelerating or decelerating. | ||
|
|
|
| DECEL: Lock by decelerating. | ||
|
|
|
| ACCEL : Lock by accelerating. | ||
|
|
|
|
|
|
|
304 | EDIT FIELD SELECT |
| Select with which fields to start and end editing using tape. | |||
|
|
|
| 1F : Start editing with field 1 and end with field 2. | ||
|
|
|
| 2F: Start editing with field 2 and end with field 1. | ||
|
|
|
| 1F/2F: Start and end editing depending on the timing of command reception. | ||
|
|
|
|
|
| |
|
|
|
| Note |
| |
|
|
|
| The setting is always 1F in the following cases. | ||
|
|
|
| • In PsF mode | ||
|
|
|
| • When SDTI (option) is selected | ||
|
|
|
| |||
305 | SYNC GRADE |
| When editing in | |||
|
|
|
| the target phase synchronization accuracy. | ||
|
|
|
| ACCUR : ±0 frame accuracy | ||
|
|
|
| ROUGH: ±1 frame accuracy | ||
|
|
|
|
|
|
|
|
|
|
|
|
| (Continued) |