Page 1
Item | Setting |
|
|
F1 (TCG) | Selects the signal source to which the internal time code generator synchronizes. |
| INT: Synchronize according to the initial preset value set by control panel operation or by remote control |
| from the device connected to the |
| playback tape. |
| EXT: Synchronize to the time code signal input to the TIME CODE IN connector. |
| SDI: Synchronize to the time code data superimposed on the HDSDI signal input to the HDSDI INPUT |
| connector. |
| SDTI: Synchronize to the time code data superimposed on the SDTI signal input to the SDTI connector. |
| (only when option is installed) |
|
|
F2 (PR/RGN) | Selects one of the following for time code generated by the internal time code generator. |
| PRESET: Presets the initial value of time code generated by the internal time code generator, as specified |
| by control panel operation or by remote control from the device connected to the |
| connector. This operation is enabled when F1 (TCG) is set to INT. At other times, the operation is the |
| same as when LTC is selected. |
| LTC: Regenerate by synchronizing to the LTC time code value read by the internal time code reader. |
| VITC: Regenerate by synchronizing to the VITC time code value read by the internal time code reader. |
|
|
F3 (RUN) | Selects one of the following running modes for the internal time code generator. |
| FREE: The time code continues to increase as long as the unit is powered on, regardless of the unit’s |
| operating mode. |
| REC: Time code increases during recording only. If you select this mode, you should also set F1 (TCG) to |
| INT, and set F2 (PR/RGN) to PRESET. |
|
|
F4 (DF) | In 59.94i, 29.97PsF mode, selects either |
| generator and the CTL counter. |
| DF: |
| NDF: |
F6 (TCR) | Selects the type of time code to display in the time data display. |
| LTC: Display LTC. |
| AUTO: Display VITC when tape speed is 1/2 or less of normal speed, and LTC otherwise. |
| VITC: Display VITC. |
|
|
Menu Function 9 Chapter