2-9-3. PICTURE TUBE BRACKET ASSY REMOVAL (KP-53S65C/61S65C)

Disassemble HA board and speaker cord.

Disassemble all the harness from purse lock.

3 Two screws (Tapping screw 4X20)

4 Shield board

6Picture tube bracket assy

5 Eight screws

(Head tapping screw 4X20)

7 Two screws (+BVTP 4X12)

8 X-RAY shield (L)

1 Three screws

(Head tapping screw 4X20)

Cabinet assy

0X-RAY shield (R)

9 Two screws

2 Chassis assy

(+BVTP 4X12)

 

except KP-61S65C

1)Remove 1 three screws (head tapping screw 4X20) and pull out 2 chassis assy from cabinet assy.

2)Remove 3 two screws (tapping screw 4X20) and remove 4 shield board.

3)Remove 5 eight screws (head tapping screw 4X20) and release 6 picture tube bracket assy from cabinet assy.

4)Remove 7 two screws (+BVTP 4X12) and remove 8 X-RAY shield (L).

5)Remove 9 two screws (+BVTP 4X12) and remove 0 X-RAY shield (R).

except KP-61S65C

– 29 –