5-4-3. Vc PWM Duty (H) adjustment method

1.Set the Manual mode and set the item No. to 763. LCD display

763 VchPWM XX

2.Connect a digital voltmeter to TP901(VC) on the main board and adjust VOL+ key and VOL– key on the remote control.

Adjustment value:2.75V Standard value:2.74 to 2.755V

MAIN BOARD (SIDE B)

digital voltmeter

TP901 (VC)

3.Press X key to write the adjustment value.(Item No. will change to 764)

MZ-E501

3.Press X key to write the adjustment value.

The adjustment completion display appears as follows. LCD display

000 ADJ OK

5-4-5.Electrical offset adjustment method

Note: Doing adjustment by the state that a disc does not enter.

1.Confirm the power voltage is 1.5V.

2.Set to the test mode.

3.Press the VOL– key activates the overall adjustment mode. LCD display

000 Assy11

4.Press the DISPLAY key. LCD display

030 Ofst**

5.If result of electrical offset adjustment is OK,the following display appears.

LCD display

030OfstOK

5-5. OVERALL ADJUSTMENT MODE

5-5-1. Overall adjustment mode structure

5-4-4. VLL PWM Duty adjustment method

1.Set the Manual mode and set the item No. to 764. LCD display

764 Vl PWM XX

2.Connect a digital voltmeter to TP904 (VL) on the main board and adjust VOL+ key and VOL– key on the remote control.

Adjustment value:2.23V Standard value:2.22 to 2.235V

MAIN BOARD (SIDE B)

TEST MODE (Display Check Mode)

VOL – key

Overall Adjustment Title Display(ASSY**)

.key

>N key

CD overall

x key

Adjustment

 

> N key

MO overall

x key

Adjustment

 

digital voltmeter

TP904 (VL)

Note: The overall adjustments should be always performed in the sequence of CD t MO adjustments.

5-5-2. Overall CD and MO adjustment method

1.Set the TEST MODE and press VOL– key to set the Overall Adjustment mode.

LCD display

000 Assy11

2.Insert CD disc in the set, and press . key to set the Overall CD Adjustment mode.

Automatic adjustments are made.

LCD display

XXXCD RUN

XXX:Item No. for which an adjustment is being executed.