MZ-E501

4-6. SELF-DIAGNOSTIC DISPLAY MODE

4-6-1. Outline of the function

The Self-diagnostic system is used in this set. If an error occurs during playback, this system detects the fault through the microprocessor’s mechanism and power control blocks and stores the cause in EEPROM in a history format.

This history, which can be viewed in the TEST MODE, provides the means of locating the fault in troubleshooting.

4-6-2. Self-diagnostic mode

1.Set the TEST MODE.

2.With all the LCD display segments blinking on the set, press DISPLAY key and the Self-diagnostic mode is entered.

001 1 Adrs

3.Hereinafter, each time > N key is pressed, the reference information display changes as follows:

0XX

1

# # # #

0XX

 

 

N

# # # #

0XX N1 # # # #

0XX N2 # # # #

0XX R – – – –

History code

Simplified contents

 

Error display code

• Press .

key to go back to the previous display.

• Contents of the history codes

 

 

 

 

History code number

Contents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

The first error that occurred.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

The last error that occurred.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N-1

 

The first error from the last one.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N-2

 

The second error from the last one.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

Total recording time ( – – – – is displayed

 

 

 

 

 

 

for MZ-E501)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Description of the error display codes

 

 

 

 

Contents of fault

Display code

Meaning of code

Simplified

 

Description

contents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No error

00

No error

– – – –

No error

 

 

 

 

 

 

 

 

 

01

Access target address illegally specified

Adrs

An attempt to access an abnormal address.

 

 

 

 

 

 

 

Servo system error

 

02

HIGH TEMP

Temp

HIGH TEMP

 

 

 

 

 

 

 

 

 

03

FOCUS ERROR

Fcus

Focus off-center.

 

 

 

 

 

 

 

 

 

 

 

04

SPINDLE ERROR

Spdl

Abnormal rotation of disc

 

 

 

 

 

 

TOC error

11

TOC ERROR

TOC

Faulty TOC contents

 

 

 

 

 

 

Power system error

12

READ DATA ERROR

Data

Data could not be read at SYNC

 

 

 

 

 

 

 

 

 

22

LOWBATT

LBat

Instantaneous interruption detected.

 

 

 

 

 

 

 

 

 

31

OFFSET ERROR

Ofst

Offset error

 

 

 

 

 

 

 

Offset error

32

FE_ABCD_OFFSET_ERR

ABCD

FE ABCD Offset error

 

 

 

 

 

 

 

 

 

33

TE_OFFSET_ERR

TE

TE Offset error

 

 

 

 

 

 

 

 

 

34

X1_TE_OFFSET_ERR

X1TE

X1 TE Offset error

 

 

 

 

 

 

 

 

 

4-6-3. Clearing the error display code After servicing, reset the error display code.

1.Set the TEST MODE.

2.Pressing the DISPLAY key on the remote control activates the self-diagnosis display mode.

3.To reset the error display code, press X key (2 times)on the remote control when the code is displayed. (except “R - - - -” ) (All the data on the 1st, N, N-1 and N-2 will be reset)

10

Page 10
Image 10
Sony MX-E501 service manual SELF-DIAGNOSTIC Display Mode, Self-diagnostic mode