MZ-E501
4-6. SELF-DIAGNOSTIC DISPLAY MODE
4-6-1. Outline of the function
The
This history, which can be viewed in the TEST MODE, provides the means of locating the fault in troubleshooting.
4-6-2. Self-diagnostic mode
1.Set the TEST MODE.
2.With all the LCD display segments blinking on the set, press DISPLAY key and the
001 1 Adrs
3.Hereinafter, each time > N key is pressed, the reference information display changes as follows:
0XX | 1 | # # # # |
0XX |
|
|
N | # # # # |
0XX N1 # # # #
0XX N2 # # # #
0XX R – – – –
History code | Simplified contents |
| |
Error display code | • Press . |
key to go back to the previous display.
• Contents of the history codes
|
|
|
| History code number | Contents | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
| The first error that occurred. | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| N |
| The last error that occurred. | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| The first error from the last one. | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| The second error from the last one. | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| R |
| Total recording time ( – – – – is displayed | |
|
|
|
|
|
| for | ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
• Description of the error display codes |
|
|
|
| ||||
Contents of fault | Display code | Meaning of code | Simplified |
| Description | |||
contents |
| |||||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
No error | 00 | No error | – – – – | No error | ||||
|
|
|
|
|
|
| ||
|
| 01 | Access target address illegally specified | Adrs | An attempt to access an abnormal address. | |||
|
|
|
|
|
|
| ||
Servo system error |
| 02 | HIGH TEMP | Temp | HIGH TEMP | |||
|
|
|
|
|
|
|
| |
| 03 | FOCUS ERROR | Fcus | Focus | ||||
|
| |||||||
|
|
|
|
|
|
| ||
|
| 04 | SPINDLE ERROR | Spdl | Abnormal rotation of disc | |||
|
|
|
|
|
| |||
TOC error | 11 | TOC ERROR | TOC | Faulty TOC contents | ||||
|
|
|
|
|
| |||
Power system error | 12 | READ DATA ERROR | Data | Data could not be read at SYNC | ||||
|
|
|
|
|
|
| ||
|
| 22 | LOWBATT | LBat | Instantaneous interruption detected. | |||
|
|
|
|
|
|
| ||
|
| 31 | OFFSET ERROR | Ofst | Offset error | |||
|
|
|
|
|
|
| ||
Offset error | 32 | FE_ABCD_OFFSET_ERR | ABCD | FE ABCD Offset error | ||||
|
|
|
|
|
|
| ||
|
| 33 | TE_OFFSET_ERR | TE | TE Offset error | |||
|
|
|
|
|
|
| ||
|
| 34 | X1_TE_OFFSET_ERR | X1TE | X1 TE Offset error | |||
|
|
|
|
|
|
|
|
|
1.Set the TEST MODE.
2.Pressing the DISPLAY key on the remote control activates the
3.To reset the error display code, press X key (2 times)on the remote control when the code is displayed. (except “R - - -
10