MZ-E501
4-4. MANUAL MODE
4-4-1. Outline of the function
The Manual mode is designed to perform adjustments and operational checks on the set’s operation according to each individual function.
Usually, no adjustments are made in this mode.
However, the Manual mode is used to clear the memory before performing automatic adjustments in the Overall Adjustment mode.
4-4-2. How to set the Manual mode
1.Set the TEST MODE and press VOL+ key to set the Manual mode. Remote control LCD display
000Manual
2.During each test, press and hold down > N key or . key for a while to move the optical pickup on the sled outer or inner perimeter.
3.Each test item is assigned with a
4.During each test mode, the display is changed from one to another each time DISPLAY key is pressed.
•Address & Adjusted Value Display LCD display
011C68S5E
adress | adjusted value |
mode number
•Jitter Value & Adjusted Value Display LCD display
011OFEJ5E
jitter value | adjusted value |
mode number
•Block Error Value & Adjusted Value Display LCD display
011063B5E
Change Major
Item
|
|
|
|
|
|
|
|
|
| key |
| x key | |
|
|
|
| |||
| > N |
| ||||
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Change Middle |
| |||
|
| Item |
|
|
| |
|
|
| key |
| x key | |
|
|
|
| |||
| > N | |||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Change Minor |
| ||
|
|
| Item |
|
|
|
VOL+ key : 100th place of mode number increase
VOL– key : 100th place of mode number decrease
VOL+ key : 10th place of mode number increase
VOL– key : 10th place of mode number decrease
>N key : Unit place of mode number increase
.key : Unit place of mode number decrease
|
|
|
|
| adjusted value |
block error value |
mode number
•ADIP Error Value & Adjusted Value Display LCD display
011072A5E
|
|
|
|
| adjusted value |
ADIP error value |
mode number
•Focus Drive Voltage Value & Adjusted Value Display
011000F5E
|
|
|
|
| adjusted value |
forcus |
| drive | |||
| |||||
voltage value |
|
Change Adjustment | VOL+ | key : Up |
Value |
| key : Down |
VOL– |
Write Adjustment
Value
Xkey : When adjusted value is changed : Adjusted value is written.
When adjusted value is not changed : That item is adjusted automatically.
mode number
•Item Title Display LCD display
011 LrefPw 5E
item |
| title | adjusted value |
|
mode number
Note: In the Power mode, the item title display is only displayed.
5.To terminate the Manual mode and return to the TEST MODE, press x key.
4-5. OVERALL ADJUSTMENT MODE
This mode is designed to adjust the servo system automatically by going through all the adjustment items.
The power adjustment manual setting is performed in this mode also. Usually, this mode is used to perform automatic adjustments when servicing the set.
For further information, refer to section 5. ELECTRICAL ADJUSTMENTS. (See page 12)
9