Sony MZ-E505 service manual 000Manual, 011XXXS5E, 011OFEJ5E, 011063B5E, 011072A5E, 011LrefPw 5E

Models: MZ-E505

1 46
Download 46 pages 11.01 Kb
Page 14
Image 14
4-3. TEST MODE STRUCTURE

MZ-E505

4-3. TEST MODE STRUCTURE

Test Mode

(Display Check Mode)

VOL +

 

 

Manual Mode

x key

 

VOL +

Servo Mode

 

Audio Mode

VOL

Power Mode

 

 

OP Alignment Mode

.

 

Overall Adjustment Mode

x key

 

DISPLAY key

 

x

Self-diagnostic Display Mode

key

>B

 

x key

 

Sound Skip Check Result Display Mode

DISPLAY key

 

(Press and hold down about 3 sec)

 

Key Check Mode

Terminate key checking or open the top panel.

4-4. MANUAL MODE

4-4-1. Outline of the function

The Manual mode is designed to perform adjustments and operational checks on the set’s operation according to each individual function.

Usually, no adjustments are made in this mode.

However, the Manual mode is used to clear the memory before performing automatic adjustments in the Overall Adjustment mode.

4-4-2. How to set the Manual mode

1.Set the TEST MODE and turn the control towerd VOL + to set the Manual mode.

Remote control LCD display

000Manual

2.During each test, turn and hold the control towerd > N or

. for a while to move the optical pickup on the sled outer or inner perimeter.

3.Each test item is assigned with a three-digit item number. The 100th place is a major item, 10th place is a middle item, and unit place is a minor item.

 

 

 

 

 

 

 

 

 

VOL +

 

 

: 100th place of mode number

 

Change Major

 

 

 

 

 

 

 

 

 

 

 

increase

 

 

Item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOL

 

 

: 100th place of mode number

 

 

 

 

 

x key

 

 

decrease

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: 10th place of mode number

 

 

 

 

 

 

 

 

 

 

 

 

 

Change Middle

 

 

VOL +

 

 

 

 

 

 

 

 

 

increase

 

 

Item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOL

 

 

: 10th place of mode number

 

 

 

 

 

x key

 

 

decrease

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Unit place of mode number

 

Change Minor

 

 

> N

 

 

 

 

 

 

 

increase

 

 

Item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.

: Unit place of mode number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

decrease

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Up

 

 

 

 

 

 

 

Change Adjustment

 

VOL +

 

 

 

 

 

 

 

Value

 

 

 

 

 

 

 

: Down

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOL

 

 

Write Adjustment

Value

Xkey : When adjusted value is changed : Adjusted value is written.

When adjusted value is not changed : That item is adjusted automatically.

4.During each test mode, the display is changed from one to another each time DISPLAY key is pressed.

Address & Adjusted Value Display LCD display

011XXXS5E

address

adjusted value

mode number

Jitter Value & Adjusted Value Display LCD display

011OFEJ5E

jitter value

adjusted value

mode number

Block Error Value & Adjusted Value Display LCD display

011063B5E

 

 

 

 

 

adjusted value

block error value

mode number

ADIP Error Value & Adjusted Value Display LCD display

011072A5E

 

 

 

 

 

adjusted value

ADIP error value

mode number

Item Title Display LCD display

011 LrefPw 5E

item

 

title

adjusted value

 

mode number

Note: In the Power mode, the item title display is only displayed.

14

Page 14
Image 14
Sony MZ-E505 service manual 000Manual, 011XXXS5E, 011OFEJ5E, 011063B5E, 011072A5E, 011LrefPw 5E, Test Mode Structure