![5-6. LED VOLTAGE ADJUSTMENTS](/images/new-backgrounds/28322/2832241x1.webp)
Item No. | Contents |
|
|
230 | Tracking servo ON |
|
|
236 | ABCD gain adjustment |
|
|
237 | KF gain adjustment |
|
|
238 | RF gain adjustment |
|
|
244 | FCS gain adjustment |
|
|
245 | TRK gain adjustment |
|
|
| READ GRV adjustment 1 |
|
|
100 | R GRV setting |
|
|
562 | SLED move to outside |
|
|
120 | Focus servo OFF |
|
|
122 | TON offset adjustment |
|
|
121 | TE gain adjustment |
|
|
122 | TON offset adjustment |
|
|
123 | TEIN offset adjustment |
|
|
124 | TWPP offset adjustment |
|
|
130 | Tracking servo ON |
|
|
131 | TWPP offset adjustment |
|
|
136 | ABCD gain adjustment |
|
|
137 | KF gain adjustment |
|
|
139 | ADIP BPF fo adjustment |
|
|
144 | FCS gain adjustment |
|
|
145 | TRK gain adjustment |
|
|
134 | TWPP gain adjustment |
|
|
131 | TWPP offset adjustment 1 |
|
|
132 | TWPP offset adjustment 2 |
|
|
149 | TWPP OP offset adjustment |
|
|
138 | RF gain adjustment |
|
|
100 | R GRV setting • Servo OFF |
|
|
5-6. LED VOLTAGE ADJUSTMENTS
5-6-1. LED voltage check
Connection:
digital voltmeter
MAIN board
TP902 (VCOUT)
TP815 (LEDADJ)
Procedure:
1.Confirm the power voltage is at 1.5 V.
2.Set to the test mode.
3.Set the Manual mode and set the item No. to 071.
Connect a digital voltmeter to TP902 (VCOUT) and TP815 (LEDADJ) on the MAIN board and confirm the voltage (high luminosity RED voltage value).
LCD display
071 Red35H XX
XXX: A/D value.
4.Turn the control towards VOL + four times to change the item No. to 075.
Connect a digital voltmeter to TP902 (VCOUT) and TP815 (LEDADJ) on the MAIN board and confirm the voltage (high luminosity GREEN voltage value).
LCD display
075 GRN35H XX
XXX: A/D value.
21