Sony MZ-E505 service manual flow chart of judging LED voltage is OK or NG

Models: MZ-E505

1 46
Download 46 pages 11.01 Kb
Page 22
Image 22
flow chart of judging LED voltage is OK or NG:

MZ-E505

5.Judge LED voltage value is OK or NG by using the voltage value confirmed at step 3 and 4.

IN case of jadgment result is NG, adjust the LED voltage (See page 23).

flow chart of judging LED voltage is OK or NG:

 

 

Vred: High luminosity RED voltage value (item No. 071)

 

 

Strat

Vgrn: High luminosity GREEN voltage value (item No. 075)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.500mV Vred 1.100mV?

 

 

 

 

 

 

 

 

 

 

Vred 1.101mV

 

 

 

Vred

0.419mV

 

0.420mV Vred 0.499mV

 

 

 

 

 

 

 

 

OK

 

 

NG

 

 

 

NG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vred-Vgrn (adsolute value)

 

 

 

 

Vred-Vgrn (adsolute value)

 

 

 

 

 

2.000mV?

 

 

 

 

 

 

 

2.000mV?

OK

8-2. LED voltage adjustment

(See page 23)

OK

2.300mVManual background VgrnManual background4.500mV?

OK

NG

 

 

 

 

 

 

 

Vgrn

4.501mV

 

Vgrn

1.349mV

1.350mV

Vgrn

2.299mV

Vgrn-Vred (absolute value)

NG

NG

Vgrn-Vred (absolute value)

 

 

3.500mV?

 

 

 

 

0.800mV?

 

 

OK

8-2. LED voltage adjustment

OK

 

 

 

(See page 23)

 

 

 

Set the item No. to 081 and confirm the LED color is orange.

End