5-4-3. VI PWM Duty adjustment

MZ-E505

5-4-3. VI PWM Duty adjustment

Connection:

5-5. OVERALL ADJUSTMENT MODE

5-5-1. Overall adjustment mode structure

digital voltmeter

MAIN board

TP904 (VL)

TP921 (GND) 5-5. OVERALL ADJUSTMENT MODE

Procedure:

1.Set the Manual mode and set the item No. to 764. LCD display

764 VlPWM XX

TEST MODE (Display Check Mode)

VOL 5-5-1. Overall adjustment mode structure764 VlPWM XX

Overall Adjustment Title Display(ASSY**)

.

> N

CD overall

 

x key

Adjustment

 

 

 

 

 

 

 

 

 

 

 

 

 

> N

 

 

 

 

 

x key

 

 

MO overall

 

Adjustment

 

 

 

 

 

 

 

2.Connect a digital voltmeter to TP904 (VL) and TP921 (GND) on the main board and adjust VOL + (Voltage up) and VOL – (Voltage down) on the remote control.

Adjustment value:2.23V Standard value:2.22 to 2.235V

3.Press X key to write the adjustment value.

5-4-4. Vb A/D value check

1.Set the Manual mode and set the item No. to 731. LCD display

731 Vb_AD XX

2.Confirm the A/D value is 73 to 87 hex.

3.Confirm the power supply consumiption current is 120 mA or less.

5-4-5.Electrical offset adjustment method

Note: Doing adjustment by the state that a disc does not enter.

1.Confirm the power voltage is 1.5V.

2.Set to the test mode.

3.Turn the control towards VOL – activates the overall adjust- ment mode.

LCD display

000 Assy11

4.Press the DISPLAY key. LCD display

035 Ofst**

5.If result of electrical offset adjustment is OK,the following dis- play appears.

LCD display

000OfstOK

 

DISPLAY

key

Electrical offset

x key

 

 

 

 

 

 

 

 

key

Adjustment key

x key

 

 

 

 

 

 

 

 

PLAY MODE

Power Supply

 

 

 

 

 

 

 

 

Adjustment

 

 

 

 

 

 

 

 

Note: The overall adjustments should be always performed in the sequence of CD t MO adjustments.

5-5-2. Overall CD and MO adjustment method

1.Set the TEST MODE and turn the control towards VOL – to set the Overall Adjustment mode.

LCD display

000 Assy11

2.Insert CD disc in the set, and turn the control towards . to set the Overall CD Adjustment mode.

Automatic adjustments are made.

LCD display

XXXCD RUN

XXX:Item No. for which an adjustment is being executed.

3.If NG in the overall CD adjustments, return to Reset NV and perform from the electrical offset adjustment again.

LCD display

000XXX NG

XXX:NG item No.

4.If OK through the overall CD adjustments, then perform overall MO adjustments.

LCD display

000CD OK

5.Insert MO disc in the set, and turn the control towards > N to set the Overall MO Adjustment mode. Automatic adjustments are made.

LCD display

XXXMO RUN

XXX:Item No. for which an adjustment is being executed.

19