Sony MZ-E505 Description of the error display codes, Contents of fault, Meaning of code

Models: MZ-E505

1 46
Download 46 pages 11.01 Kb
Page 16
Image 16
• Description of the error display codes

MZ-E505

• Description of the error display codes

Contents of fault

Display code

Meaning of code

Simplified

Description

contents

 

 

 

 

 

 

 

 

 

No error

00

No error

– – – –

No error

 

 

 

 

 

 

01

Access target address illegally specified

Adrs

An attempt to access an abnormal address.

 

 

 

 

 

Servo system error

02

HIGH TEMP

Temp

HIGH TEMP

03

FOCUS ERROR

Fcus

Focus off-center.

 

 

 

 

 

 

 

04

SPINDLE ERROR

Spdl

Abnormal rotation of disc

 

 

 

 

 

TOC error

11

TOC ERROR

TOC

 

12

READ DATA ERROR

Data

 

 

 

 

 

 

 

 

Power system error

22

LOWBATT

LBat

Instantaneous interruption detected.

 

31

OFFSET ERROR

Ofst

Offset error

Offset error

32

FE_ABCD_OFFSET_ERR

ABCD

FE ABCD Offset error

 

33

TE_ABCD_OFFSET_ERR

TE

TE ABCD Offset error

 

34

X1_TE_OFFSET_ERR

X1TE

X1 TE ABCD Offset error

 

 

 

 

 

4-6-3. Clearing the error display code

After servicing, reset the error display code.

1.Set the TEST MODE.

2.Press the DISPLAY key on the remote control activates the self- diagnosis display mode.

3.To reset the error display code press X key on the remote con- trol when the code is displayed.(except for R_ - - - - display) (All the data on the 1, N, N1 and N2 will be reset)

4.Press X key on the remote control again.