SECTION 4
TEST MODE
OUTLINE
A key having no particular description in the text, indicates a set key.
1.ENTERING THE TEST MODE
Preparation:
Copy the “TestMode_Enter_For_NH1_NH3D_Ver***.exe” folder of the PC application of the latest version to your PC in advance. (operating system: Windows 2000, Windows XP)
Also, when using this application, the SonicStage Ver. 2.0 or 2.1 is necessary, and install it in your PC in advance.
Procedure:
1.If a Simple Burner has run on the PC, finish it (including the one that is resident in the task tray).
2.Start the “TestMode_Enter_For_NH1_NH3D_Ver***.exe”.
3.Insert the fully charged
4.Open and close the top panel of the main unit to wait until the system reading finished.
5.Connect the main unit and PC by USB cable.
6.Check by device manager screen from property of “My computer” that the set is recognised to your PC normally.
7.Click the [EnterTestMode] button on the screen of application
8.Disconnect the USB cable, when “OK” message is displayed on the application screen.
9.Remove the
Screen of the PC application “TestMode_Enter_For_NH1_NH3D_ Ver***.exe”
(“***” is version number)
Note: Once the test mode is activated with this application, the test mode is then activated forcibly by only turning on the power.
After the repair completed, be sure to release the test mode by using this application once more.
2.OPERATION IN SETTING THE TEST MODE
•When the test mode becomes active, first the Display Check mode is selected.
•Other mode can be selected from the Display Check mode.
•When the test mode is set, the LCD repeats the following display.
•When the x key is pressed and hold down, the display at that time is held so that display can be checked.
Display check mode:
•Display of the main unit
All lit
All off
Microcomputer version display
Ver *.***
•Display of the remote commander
All lit
All off |
|
|
Microcomputer | 001 |
|
version | Ver | *.*** |
display |
|
|
3.RELEASING THE TEST MODE
Procedure:
1.If a Simple Burner has run on the PC, finish it (including the one that is resident in the task tray).
2.Start the “TestMode_Enter_For_NH1_NH3D_Ver***.exe”.
3.Insert the fully charged
4.Open and close the top panel of the main unit to wait until the system reading finished.
5.Connect the main unit and PC by USB cable.
6.Check by device manager screen that the set is recognised to your PC normally.
7.Click the [Exit TestMode] button on the screen of application
8.Disconnect the USB cable, when “OK” message is displayed on the application screen.
9.Remove the
12