3-7. Setting The Adjustment Values
3-7-1. Hi-MD3 setting
Preparation:
1.Perform calculation every item based on the data given by the
2.Convert the calculated value into hexadecimal number.
Note: The
Item No. | Calculating formula (*3) |
|
|
0211 | Pr_nominal / 0.05 |
|
|
(*1) | Por / 0.05 |
|
|
0212 | Kr ⋅ (−100) |
|
|
0213 | Pw_nominal / 0.05 |
|
|
(*2) | Ppw / 0.05 |
|
|
0214 | Kw ⋅ (−100) |
|
|
0215 | Prmin / 0.05 |
|
|
0216 | Pwmin / 0.05 |
|
|
*1) If the “Pr_nominal” value is indicated, use the “Pr_nominal” value and not used “Por” value.
*2) If the “Pw_nominal” value is indicated, use the “Pw_nominal” value and not used “Ppw” value.
*3) Round off after the decimal point.
Table 3-7-1. Hi-MD3 adjustment parameter
Example of Calculation:
Item No. | Parameter |
| Result | ||
|
| ||||
Decimal | Hexadecimal | ||||
|
|
| |||
|
|
|
|
| |
0211 | Pr_nominal | 2.50 mW | 50 | 32h | |
|
|
|
|
| |
0212 | Kr | −0.3 %/°C | 30 | 1Eh | |
|
|
|
|
| |
0213 | Pw_nominal | 7.35 mW | 147 | 93h | |
|
|
|
|
| |
0214 | Kw | −0.4 %/°C | 40 | 28h | |
|
|
|
|
| |
0215 | Prmin | 1.9 mW | 38 | 26h | |
|
|
|
|
| |
0216 | Pwmin | 5.8 mW | 116 | 74h | |
|
|
|
|
|
Procedure:
1.In the test mode (Display Check mode), press the [VOL+] key to enter the Manual mode.
2.Press the [FF] key once, press the [VOL+] key once, and press the [FF] key once again to display as follows.
Display of the remote commander
210
PwrAdj
3.Press the [FF] key once to select the item number 0211.
4.Adjust with
5.Press the X key to write the adjusted value.
6.Press the [FF] key to next item.
7.Repeat adjustment from step 4 until item number 0216.
3-7-2. Other setting
1.In the test mode (Display Check mode), press the [VOL+] key to enter the Manual mode.
2.Press the [FF] key five time to select the item number 0113 and display as follows.
Display of the remote commander
113
DistF **
adjustment value (hexadecimal)
3.Press the
4.Press the X key to write the adjusted value.
Destination | Setting value | |
US, Australian | 01 | |
|
| |
AEP, UK | 81 | |
|
| |
E18, Hong Kong, Taiwan, | 05 | |
Korean, Chinese, Tourist | ||
|
•Abbreviation
E18: 100V - 240V AC area in E model
Table 3-7-2. Mode Type and Destination Setting
3-8. Servo Overall Adjustment
Note1: Be sure to adjustment so that the set is horizontal and the LCD is upside. Unless performed in that state, it is not adjusted correctly.
Note2: If NG is displayed in the middle of this adjustments, perform
Procedure:
1.Insert the full charged
2.Press the
3.Insert the CD adjustment disc
4.Put the main unit horizontal so that the LCD becomes upside, and press the [FR] key.
5.Wait until “CD OK” is displayed on the LCD.
6.Insert the MD1/HiMD1 hybrid adjustment disc
7.Put the main unit horizontal so that the LCD becomes upside, and press the [FF] key.
8.Wait until “MD1 OK” is displayed on the LCD.
9.Insert the
10.Put the main unit horizontal so that the LCD becomes upside, and press the [VOL+] key.
11.Wait until “HMD OK” is displayed on the LCD.
12.Eject the disc.
13.Put the main unit horizontal so that the LCD becomes upside, and press the
14.Wait until “OfstOK” is displayed on the LCD.
15.Press the x key and back to the Display Check mode.