3-7. Setting The Adjustment Values

3-7-1. Hi-MD3 setting

Preparation:

1.Perform calculation every item based on the data given by the Hi-MD3 adjustment disc by referring to the following table. (Round off the value in decimal place)

2.Convert the calculated value into hexadecimal number.

Note: The Hi-MD3 adjustment parameters vary depending on the disc, and therefore use the parameters of the disc used when performing the adjustment.

Item No.

Calculating formula (*3)

 

 

0211

Pr_nominal / 0.05

 

 

(*1)

Por / 0.05

 

 

0212

Kr (100)

 

 

0213

Pw_nominal / 0.05

 

 

(*2)

Ppw / 0.05

 

 

0214

Kw (100)

 

 

0215

Prmin / 0.05

 

 

0216

Pwmin / 0.05

 

 

*1) If the “Pr_nominal” value is indicated, use the “Pr_nominal” value and not used “Por” value.

*2) If the “Pw_nominal” value is indicated, use the “Pw_nominal” value and not used “Ppw” value.

*3) Round off after the decimal point.

Table 3-7-1. Hi-MD3 adjustment parameter

Example of Calculation:

Item No.

Parameter

 

Result

 

 

Decimal

Hexadecimal

 

 

 

 

 

 

 

 

0211

Pr_nominal

2.50 mW

50

32h

 

 

 

 

 

0212

Kr

0.3 %/°C

30

1Eh

 

 

 

 

 

0213

Pw_nominal

7.35 mW

147

93h

 

 

 

 

 

0214

Kw

0.4 %/°C

40

28h

 

 

 

 

 

0215

Prmin

1.9 mW

38

26h

 

 

 

 

 

0216

Pwmin

5.8 mW

116

74h

 

 

 

 

 

Procedure:

1.In the test mode (Display Check mode), press the [VOL+] key to enter the Manual mode.

2.Press the [FF] key once, press the [VOL+] key once, and press the [FF] key once again to display as follows.

Display of the remote commander

210

PwrAdj

3.Press the [FF] key once to select the item number 0211.

4.Adjust with [VOL+]/[VOL--]keys so that the adjustment value of LCD becomes calculated value.

5.Press the X key to write the adjusted value.

6.Press the [FF] key to next item.

7.Repeat adjustment from step 4 until item number 0216.

MZ-NH1

3-7-2. Other setting

1.In the test mode (Display Check mode), press the [VOL+] key to enter the Manual mode.

2.Press the [FF] key five time to select the item number 0113 and display as follows.

Display of the remote commander

113

DistF **

adjustment value (hexadecimal)

3.Press the [VOL+]/[VOL--]key and set the according value to each model type and destination referring to the following table.

4.Press the X key to write the adjusted value.

Destination

Setting value

US, Australian

01

 

 

AEP, UK

81

 

 

E18, Hong Kong, Taiwan,

05

Korean, Chinese, Tourist

 

Abbreviation

E18: 100V - 240V AC area in E model

Table 3-7-2. Mode Type and Destination Setting

3-8. Servo Overall Adjustment

Note1: Be sure to adjustment so that the set is horizontal and the LCD is upside. Unless performed in that state, it is not adjusted correctly.

Note2: If NG is displayed in the middle of this adjustments, perform “3-2. Initialize The Adjustment Value” and “3-7. Setting The Adjustment Values” again, then retry this adjustments from step 1.

Procedure:

1.Insert the full charged lithium-ion battery (LIP-4WM) and enter the test mode (Display Check mode).

2.Press the [VOL--]key to enter the Overall Adjustment mode.

3.Insert the CD adjustment disc (TDYS-1).

4.Put the main unit horizontal so that the LCD becomes upside, and press the [FR] key.

5.Wait until “CD OK” is displayed on the LCD.

6.Insert the MD1/HiMD1 hybrid adjustment disc (MDW-74/GA1).

7.Put the main unit horizontal so that the LCD becomes upside, and press the [FF] key.

8.Wait until “MD1 OK” is displayed on the LCD.

9.Insert the Hi-MD3 adjustment disc (HMD1GSDJ).

10.Put the main unit horizontal so that the LCD becomes upside, and press the [VOL+] key.

11.Wait until “HMD OK” is displayed on the LCD.

12.Eject the disc.

13.Put the main unit horizontal so that the LCD becomes upside, and press the [VOL--]key.

14.Wait until “OfstOK” is displayed on the LCD.

15.Press the x key and back to the Display Check mode.