4. CONFIGURATION OF THE TEST MODE

MZ-NH1

5. MANUAL MODE

This is mode to adjust or check the operation of the set by function.

Flow of the test mode:

Display Check Mode

001

Ver *.***

[VOL +] key

xkey

[VOL --] key

xkey

Version display All lit

All off Version display...

Manual Mode

000

Manual

Overall Adjustment Mode

000

AdjF**

Key Check Mode

Operation of The Manual Mode

1.Enter the test mode (Display Check mode).

2.Press the [VOL+] key to activate the Manual mode where the LCD displays as shown below.

Display of the remote commander

000

Manual

Number of 1000th place

(000 to 009)

3.

During each test, the optical pick-up moves outward or inward

 

while the [FF] or [FR] key is pressed for several seconds

 

respectively.

4.

Each test item is assigned with a four-digit item number; 1000th

 

place is a top item, 100th place is a major item, 10th place is a

 

[GROUP] key

000

 

 

 

 

10

 

 

 

 

 

Open the lid

 

 

 

 

Self-Diagnosis Result Display Mode

 

[FF] key

000

 

 

 

1

0000

 

 

 

x key

 

medium item, and unit place is a minor item.

The values adjusted in the test mode are written to the non-

volatile memory (for the items where adjustment was made).

5. To quit the Manual mode, press the x key and return to the

Display Check mode.

Flow of manual mode operation:

 

 

 

 

 

Sound Skip Check Result

 

 

 

 

 

Display Mode (Play)

 

 

 

key

000

 

 

N ENT

 

 

 

 

 

P00r00

 

 

 

 

 

 

x key

 

 

 

 

 

 

 

Sound Skip Check Result

 

 

 

 

 

Display Mode (REC)

Top item switching

[FF] key

 

x key

 

 

 

Major item switching

[FF] key

 

x key

 

 

 

[VOL +] key: 1000th place of item number increase.

[VOL --]key: 1000th place of item number decrease.

[VOL +] key: 100th place of item number increase.

[VOL --]key: 100th place of item number decrease.

 

[T MARK] key

000

 

 

 

p00R00

 

 

 

x key

 

 

 

 

 

Key Count Mode

[MENU] key

000

MENU

000

Medium item switching

[FF] key

 

x key

 

 

 

Minor item switching

[VOL +] key: 10th place of item number increase.

[VOL --]key: 10th place of item number decrease.

[FF]key: 1st place of item number increase.

[FR] key: 1st place of item number decrease.

[FF]or [FR] key (press a few seconds)

(Not used in servicing)

Adjusted value variation

[VOL +] key: Increases the adjusted value.

[VOL --]key: Decreases the adjusted value.

Adjusted value write

Xkey: Adjusted value is written.

13