Ver 1.1 | SECTION 5 |
| ELECTRICAL ADJUSTMENTS |
1.PRECAUTIONS FOR ADJUSTMENT
1.Adjustment must be done in the test mode only. After adjusting, release the test mode. A key having no particular description in the text, indicates a set key.
2.Use the following tools and measuring instruments.
•Digital voltmeter
•Regulated dc power supply (two sets)
•Thermometer (using the “Setting The Temperature Correction Value”)
•Laser power meter
•CD adjustment disc
•MD1/HiMD1 hybrid adjustment disc
•
•Remote commander in accessories (with LCD)
•Battery charging stand and AC adapter in accessories
•
•PC application software for test mode
“TestMode_Enter_For_NH1_NH3D_Ver***.exe” *2
•USB cable
*1)
*2) Use the newest version every time.
Copy the whole folder of this program to your PC. Operating system: Windows 2000, Windows XP
When using this application, the SonicStage Ver. 2.0 or 2.1 is necessary, and install it in your PC in advance.
3.Unless specified otherwise, use the AC adaptor and battery charging stand in accessories.
2.ADJUSTMENT SEQUENCE
Adjustment must be done with the following order.
Adjustment order:
1.Entering the test mode
2.Initialize the adjustment value
3.Setting the temperature correction value
4.Power supply voltage adjustment
5.Charge function check
6.Laser power check
7.Setting the adjustment values
8.Servo Overall adjustment
9.Resume clear
10.Releasing the test mode
3.ADJUSTMENT OF THE EACH ITEM 3-1. Entering The Test Mode
Refer to the “SECTION 4. TEST MODE”.
3-2. Initialize The Adjustment Value
Procedure:
1.In the test mode (Display Check mode), press the
2.Press the [T MARK] key and display “911 ResOK?”.
3.Press the X key to display “911 Reset!” and initialize the adjustment values.
4.Press the x key and back to Display Check mode.
3-3. Setting The Temperature Correction Value
Procedure:
1.In the test mode (Display Check mode), press the [VOL+] key to enter the Manual mode.
2.Press the [FF] key twice, and press the [VOL+] key twice to display as follows.
Display of the remote commander
130
Temp
3.Press the [FF] key once to select the item number 0131 and display as follows.
Display of the remote commander
131
SetTmp **
adjustment value (hexadecimal)
4.Measure the ambient temperature.
5.Adjust with
(hexadecimal value) becomes the ambient temperature. (example: 25 °C = 19h)
6.Press the X key to write the adjusted value.
7.Press the x key four times and back to the Display Check mode.
3-4. Power Supply Voltage Adjustment
Adjustment must be done with the following order.
3-4-1. Setting
Procedure:
1.Apply the voltage of 3.7 V to the battery terminals, and enter the test mode (Display Check mode).
2.Press the [VOL+] key to enter the Manual mode.
3.Press the [VOL+] key twice to display as follows.
Display of the remote commander
002
POWER
4.Press the [FF] key once, press the [VOL+] key once, and press the [FF] key once again to display as follows.
Display of the remote commander
210
PwrAdj
5.Repeat the next procedures
16