3-4-3. VBsAdj adjustments
Procedure:
1.In the
Display of the remote commander
240
VBsAdj
2.Apply the voltage of 5 V to the CL453 (VBUS 5V) and CL460 (VBUS GND).
3.Press the [FF] key to change the item number to 2241.
4.Adjust with
5.Press the X key to write the adjusted value.
6.Press the [FF] key to select the next item, and repeat adjustments to item number 2243 at the same manner as step 3 to step 5.
Item No. | Display | Specification value | Measuring point | |
|
|
|
|
|
2241 |
| 241 REG4 ** | 1.13 V ± 0.01 V | CL603 |
|
|
|
|
|
2242 |
| 242 REG5 ** | 2.05 V + 0.02 V | CL8003 |
|
|
|
|
|
2243 |
| 243 REG6 ** | 3.30 V ± 0.01 V | CL8007 |
Note1: | “**” is adjustment value (hexadecimal number). | |||
Note2: | Ground point of all adjustment points is CL433. | |||
Note3: | Refer to page 17 for adjustment location. |
|
Table 3-4-2. VBsAdj Specifications
7.Press the [FF]key to select the item number 2244, and turn off the power supply of battery terminal.
8.Adjust with
9.Press the X key to write the adjusted value.
10.Apply the voltage of 3.7 V to the battery terminal again.
11.Press the x key to display “240 VBsAdj” (Item number: 2240).
12.Turn off the voltage of 5 V to the CL453 (VBUS 5V) and CL460 (VBUS GND).
13.Press the x key three times and back to the Display Check mode.
3-5. Charge Function Check
Note1: When perform this check, don’t apply a voltage to battery terminals.
Note2: Be sure to disconnect the AC adapter when connecting the resistors. Doing so with the power supply connected causes a trouble.
Procedure:
1.Connect the 10 ohms resistor (more than 3 watts) to battery terminals.
2.Connect the AC adapter to the battery charging stand in accessories and set the main unit.
3.Enter the test mode (Display Check mode).
4.Press the [VOL+] key once to enter the Manual mode.
5.Press the [VOL+] key twice, press the [FF] key once, press the [VOL+] key once, press the [FF] key once, press the [VOL+] key twice to display as follows.
Display of the remote commander
250
ChrgLi
6.And [FF] key once again to select the item number 2251 and display “251 ChgChk **” on the LCD of remote commander.
7.Press the X key confirm that “ChgCOK” is displayed.
8.Press the x key four times and back to the Display Check mode.
9.Cut the power supply and remove the resistor that connected to the battery terminals.
3-6. Laser Power Check
Procedure:
1.In the test mode (Display Check mode), press the [VOL+] key to enter the Manual mode.
2.Open the lid and press the [FR] key continuously until the optical
3.Set the laser power meter so that the laser beam from the optical
4.Press the
Display of the remote commander
009
DESIGN
5.Press the [FF] key three times to select the item number 9111 and display as follows.
Display of the remote commander
111
LrefPw **
6.Confirm that the value of laser power meter is 0.67 mW ± 21%.
7.Press the [FF] key to select the item number 9112.
8.Confirm that the value of laser power meter is 0.76 mW ± 18%.
9.Press the [FF] key to select the item number 9113.
10.Confirm that the value of laser power meter is 6.25 mW ± 12%.
11.Press the x key four times and back to the Display Check mode.
18