Sony NWZ-X1051 service manual CH separation L-ch check Seplr, CH separation R-ch check Seprl

Models: NWZ-X1051

1 34
Download 34 pages 55.24 Kb
Page 18
Image 18

NWZ-X1050/X1051/X1060/X1061

4-2-5. CH separation (L-ch) check (SEPLR)

“1 kHz 0 dBs L-ch VOLUME: 25” audio signal is outputted.

Checking method:

1.Enter the test mode.

2.Press the [>]/[.] key to select the “AUDIO”, and press the [u] key to enter the minor item.

3.Press the [>]/[.] key to select the “SEPLR”.

4.Press the [u] key, “1 kHz 0 dBs L-ch VOLUME: 25” audio signal is outputted.

Screen display

AUDIO SEPLR 1kHz 0dBs Lch HPOUT [ VOL: 25 ]

START

5. Press the [HOME] key, return to minor item selection screen.

4-2-6. CH separation (R-ch) check (SEPRL)

“1 kHz 0 dBs R-ch VOLUME: 25” audio signal is outputted.

Checking method:

1.Enter the test mode.

2.Press the [>]/[.] key to select the “AUDIO”, and press the [u] key to enter the minor item.

3.Press the [>]/[.] key to select the “SEPRL”.

4.Press the [u] key, “1 kHz 0 dBs R-ch VOLUME: 25” audio signal is outputted.

Screen display

AUDIO SEPRL 1kHz 0dBs Rch HPOUT [ VOL: 25 ]

START

5. Press the [HOME] key, return to minor item selection screen.

4-2-7. Maximum output check (MAXOUT)

“1 kHz 0 dBs L-ch/R-ch VOLUME: 30” (Headphone output when

AVLS operates: “1 kHz 0 dBs L-ch/R-ch VOLUME: 14”) audio signal is outputted.

Checking method:

1.Enter the test mode.

2.Press the [>]/[.] key to select the “AUDIO”, and press the [u] key to enter the minor item.

3.Press the [>]/[.] key to select the “MAXOUT”.

4.Press the [u] key, “1 kHz 0 dBs L-ch/R-ch VOLUME: 30”

(Headphone output when AVLS operates: “1 kHz 0 dBs L-

ch/R-ch VOLUME: 14”) audio signal is outputted.

Screen display

AUDIO MAXOUT 1kHz 0dBs L/Rch HPOUT [ VOL: 30 ]

AVLS OFF

START

5.In this state, each time the [OPTION] key is pressed, AVLS on/ off switch is performed.

6.Press the [HOME] key, return to minor item selection screen.

4-2-8. Normalizer check (NMLZR)

“1 kHz –24 dBs L-ch/R-ch VOLUME: 30” audio signal is output- ted.

Checking method:

1.Enter the test mode.

2.Press the [>]/[.] key to select the “AUDIO”, and press the [u] key to enter the minor item.

3.Press the [>]/[.] key to select the “NMLZR”.

4.Press the [u] key, “1 kHz –24 dBs L-ch/R-ch VOLUME: 30” audio signal is outputted.

Screen display

AUDIO NMLZR

1kHz –24dBs L/Rch HPOUT [ VOL: 30 ]

START

5. Press the [HOME] key, return to minor item selection screen.