Connections

Attaching the Ferrite CoreWhen attaching to the AC power cord

1 Attach the ferrite cores to both ends of the AC power cord and close the ferrite cores until they click.

Within 10 mm (13/32 inch)

Within 10 mm (13/32 inch)

2 Wind the stopper round the cord so that the ferrite cores do not slide.

Within 10 mm (13/32 inch)

Within 10 mm (13/32 inch)

When attaching to the cables

1 Attach the ferrite core to the end of the cable closer to this unit, closing it until it clicks.

Within 10 mm (13/32 inch)

2 Wind the stopper round the cord so that the ferrite core does not slide.

Within 10 mm (13/32 inch)

3 Tighten the stopper and cut the surplus.

3 Tighten the stopper and cut the surplus.

Notes

When you connect this unit to various pieces of equipment using the RGB/YUV connectors, use the specified cable.

SMF-400 (D-Sub 15P - 5 BNC) SMF-410 (D-Sub 15P - D-Sub 15P)

When you connect a cable to any of the terminals listed below, attach the ferrite core provided before using the cable.

AUDIO (INPUT1) AUDIO (INPUT2)

You are cautioned that this unit will not be in compliance with the EMC limits unless the ferrite core is installed on the interconnecting wire.

16 (GB)